Elta SEN-HY-I Wall Mounted Humidity Sensor with Run-On Timer
Elta SEN-HY-I Wall Mounted Humidity Sensor with Run-On Timer
£89.20
SKU: SEN-HY-I

Elta SEN-HY-I Wall Mounted Humidity Sensor with Run-On Timer

Humidity sensor 50 to 95% RH
1 to 25 minute run-on timer
Single back box mounting
Exc VAT
Estimated delivery
In stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model SEN-HY-I
Brand Elta
Elta code ET-900005/A
Supply 230V 50/60Hz
Load 2A
Humidity range 50 to 95% RH
Timer 1 to 25 minutes
IP rating IP40
Operating temperature 0°C to +35°C
Warranty 1 Year parts only

Summary

The Elta SEN-HY-I is a wall mounted humidistat with a built-in run-on timer. It switches ventilation on, or to boost, when room humidity passes an adjustable set point between 50 and 95% RH, then keeps it running for 1 to 25 minutes after humidity falls.

It switches up to 2A at 230V 50/60Hz, has an LED status indicator, fits a single back box and has an IP40 rating for operating temperatures from 0°C to +35°C. Elta code ET-900005/A, with a 1 year parts only warranty.

See more specification See less specification

The Elta SEN-HY-I is a wall mounted humidistat with a built-in run-on timer. It switches ventilation on, or to boost, when room humidity passes an adjustable set point between 50 and 95% RH, then keeps it running for 1 to 25 minutes after humidity falls.

It switches up to 2A at 230V 50/60Hz, has an LED status indicator, fits a single back box and has an IP40 rating for operating temperatures from 0°C to +35°C. Elta code ET-900005/A, with a 1 year parts only warranty.

  • Humidity sensor 50 to 95% RH
  • 1 to 25 minute run-on timer
  • Single back box mounting

What it is best used for

Automatic humidity control of extract fans and the humidity boost input of whole house units: bathrooms, shower rooms, en-suites, utility rooms and drying rooms, plus remote boost of Elta HAVA MVHR units from the wet room where the moisture is produced.

It is a switching device rated at 2A, so it suits domestic fans and the switched inputs of MVHR units, not large commercial fans. It is IP40 and rated to +35°C, so do not mount it inside a shower enclosure or directly above a bath or cooker.

Why choose this over alternatives

Many domestic fans have a humidistat built in, but that sensor is in the fan, often high on a ceiling or wall away from the shower. A wall mounted SEN-HY-I senses the room itself and can boost a central unit such as the HAVA180H or HAVA280V MVHR, which has no sensor in each wet room.

For timed run-on from a light switch with no humidity sensing, the 149S-A1729 run-on timer handles up to 5A and up to 4 hours.

Installation notes

  • Mount on a single back box in the room being ventilated, away from direct steam and heat sources.
  • Wire to the fan or unit's switched (boost) input as shown in its instructions; do not exceed the 2A switching rating.
  • Set the humidity threshold and the 1 to 25 minute over-run on commissioning, then check the LED as the set point is passed.
  • Wiring by a qualified electrician with the supply isolated.

Browse more timer and humidity controllers or Elta controllers, or call us for help choosing the right product.

Specifications

Model SEN-HY-I
Brand Elta
Elta code ET-900005/A
Supply 230V 50/60Hz
Load 2A
Humidity range 50 to 95% RH
Timer 1 to 25 minutes
IP rating IP40
Operating temperature 0°C to +35°C
Warranty 1 Year parts only
Mounting Single back box
Indication LED status indicator

Product Description

The Elta SEN-HY-I is a wall mounted humidistat with a built-in run-on timer. It switches ventilation on, or to boost, when room humidity passes an adjustable set point between 50 and 95% RH, then keeps it running for 1 to 25 minutes after humidity falls.

It switches up to 2A at 230V 50/60Hz, has an LED status indicator, fits a single back box and has an IP40 rating for operating temperatures from 0°C to +35°C. Elta code ET-900005/A, with a 1 year parts only warranty.

  • Humidity sensor 50 to 95% RH
  • 1 to 25 minute run-on timer
  • Single back box mounting

What it is best used for

Automatic humidity control of extract fans and the humidity boost input of whole house units: bathrooms, shower rooms, en-suites, utility rooms and drying rooms, plus remote boost of Elta HAVA MVHR units from the wet room where the moisture is produced.

It is a switching device rated at 2A, so it suits domestic fans and the switched inputs of MVHR units, not large commercial fans. It is IP40 and rated to +35°C, so do not mount it inside a shower enclosure or directly above a bath or cooker.

Why choose this over alternatives

Many domestic fans have a humidistat built in, but that sensor is in the fan, often high on a ceiling or wall away from the shower. A wall mounted SEN-HY-I senses the room itself and can boost a central unit such as the HAVA180H or HAVA280V MVHR, which has no sensor in each wet room.

For timed run-on from a light switch with no humidity sensing, the 149S-A1729 run-on timer handles up to 5A and up to 4 hours.

Installation notes

  • Mount on a single back box in the room being ventilated, away from direct steam and heat sources.
  • Wire to the fan or unit's switched (boost) input as shown in its instructions; do not exceed the 2A switching rating.
  • Set the humidity threshold and the 1 to 25 minute over-run on commissioning, then check the LED as the set point is passed.
  • Wiring by a qualified electrician with the supply isolated.

Browse more timer and humidity controllers or Elta controllers, or call us for help choosing the right product.

Specifications

Model SEN-HY-I
Brand Elta
Elta code ET-900005/A
Supply 230V 50/60Hz
Load 2A
Humidity range 50 to 95% RH
Timer 1 to 25 minutes
IP rating IP40
Operating temperature 0°C to +35°C
Warranty 1 Year parts only
Mounting Single back box
Indication LED status indicator

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What does the Elta SEN-HY-I do?

It switches ventilation on above a set humidity level and keeps it running for a set time once humidity has dropped.

What humidity range can the SEN-HY-I be set to?

Adjustable from 50 to 95% RH.

How long is the run-on timer?

Adjustable from 1 to 25 minutes.

What load can the SEN-HY-I switch?

Up to 2A at 230V.

Can the SEN-HY-I boost an Elta HAVA MVHR unit?

Yes. It can drive the humidity or switched boost input of Elta HAVA MVHR units, as well as switch fans directly.

Can the SEN-HY-I go in a shower area?

No. It is IP40 and rated 0°C to +35°C, so mount it in the room away from direct steam and heat.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently viewed