Elta EC Electronic Controller
Suggested products
Free 14 day returns
Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.
Why choose eFans?
- Bulk pricing available
- Free help and advice
- Fast quotes, usually within the hour
- Huge range with next-day delivery
- Credit accounts available
Delivery and Warranty
Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days.
£7.95
Next Working Day Delivery
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays)
£15.95
Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95
Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95
Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95
Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95
Product Details
Downloads
Specifications
Product specifications
| Model | 149-POT-10-MI |
| Brand | Elta |
| Type | EC fan speed controller (potentiometer) |
| Control signal | 0-10V |
| Minimum speed | Adjustable by internal preset |
| Compatible with | EC fans and variable speed drives (inverters) |
Summary
See more specification See less specification
The Elta 149-POT-10-MI is a potentiometer speed controller for EC fans. It sets the fan's 0-10V speed signal with a control knob, and the minimum speed is set on an internal preset so the fan cannot be turned down below a safe ventilation rate.
Elta list it as the standard controller for their EC fan ranges, and it can also be used with variable speed drives (inverters). It is a low voltage control device: the fan keeps its own mains supply and the controller only provides the speed signal.
- 0-10V EC controller
- Potentiometer speed control
- Internal minimum speed preset
What it is best used for
Manual speed setting of EC fans in offices, classrooms, toilets, kitchens and plant rooms, where an installer or facilities team wants to set and occasionally adjust the duty. Elta list it on the accessory tables for their EC box, inline, mixed flow, long cased and plate fans, and it suits inverter driven AC fans too.
It is not a mains voltage controller, so it will not slow an ordinary AC fan; use an electronic or transformer controller for those. If the fan needs to step up to a boost speed on a switch, the trickle and boost version is the better fit.
Why choose this over alternatives
Elta specify this controller across their EC ranges on eFans, including the SSDL and STDL box fans, Jetflow SJMF inline fans, SLC EC long cased fans, SEL EC mixed flow fans and the SPA710/6-1EC. Because the fan's EC motor does the speed regulation, there is no hum and no heat in the controller.
For a manual trickle and boost switch, use the 149-POT-10-TB. For BMS enable, fan fail relay and 0-10V sensor input, step up to the 149-EC-TB trickle and boost controller.
Installation notes
- Wire the controller to the fan's control terminals (typically 10V, 0-10V input and GND) using the fan's Elta wiring diagram, keeping control cable separate from mains cable.
- Set the internal minimum speed preset during commissioning so the fan always delivers the design minimum airflow.
- Isolate the fan's mains supply before connecting the control wiring. Installation by a qualified electrician.
Browse more fan speed controllers or Elta controllers, or call us for help choosing the right product.
Specifications
| Model | 149-POT-10-MI |
| Brand | Elta |
| Type | EC fan speed controller (potentiometer) |
| Control signal | 0-10V |
| Minimum speed | Adjustable by internal preset |
| Compatible with | EC fans and variable speed drives (inverters) |
Manuals & Guides
Product Description
The Elta 149-POT-10-MI is a potentiometer speed controller for EC fans. It sets the fan's 0-10V speed signal with a control knob, and the minimum speed is set on an internal preset so the fan cannot be turned down below a safe ventilation rate.
Elta list it as the standard controller for their EC fan ranges, and it can also be used with variable speed drives (inverters). It is a low voltage control device: the fan keeps its own mains supply and the controller only provides the speed signal.
- 0-10V EC controller
- Potentiometer speed control
- Internal minimum speed preset
What it is best used for
Manual speed setting of EC fans in offices, classrooms, toilets, kitchens and plant rooms, where an installer or facilities team wants to set and occasionally adjust the duty. Elta list it on the accessory tables for their EC box, inline, mixed flow, long cased and plate fans, and it suits inverter driven AC fans too.
It is not a mains voltage controller, so it will not slow an ordinary AC fan; use an electronic or transformer controller for those. If the fan needs to step up to a boost speed on a switch, the trickle and boost version is the better fit.
Why choose this over alternatives
Elta specify this controller across their EC ranges on eFans, including the SSDL and STDL box fans, Jetflow SJMF inline fans, SLC EC long cased fans, SEL EC mixed flow fans and the SPA710/6-1EC. Because the fan's EC motor does the speed regulation, there is no hum and no heat in the controller.
For a manual trickle and boost switch, use the 149-POT-10-TB. For BMS enable, fan fail relay and 0-10V sensor input, step up to the 149-EC-TB trickle and boost controller.
Installation notes
- Wire the controller to the fan's control terminals (typically 10V, 0-10V input and GND) using the fan's Elta wiring diagram, keeping control cable separate from mains cable.
- Set the internal minimum speed preset during commissioning so the fan always delivers the design minimum airflow.
- Isolate the fan's mains supply before connecting the control wiring. Installation by a qualified electrician.
Browse more fan speed controllers or Elta controllers, or call us for help choosing the right product.
Specifications
| Model | 149-POT-10-MI |
| Brand | Elta |
| Type | EC fan speed controller (potentiometer) |
| Control signal | 0-10V |
| Minimum speed | Adjustable by internal preset |
| Compatible with | EC fans and variable speed drives (inverters) |
Manuals & Guides
Delivery & Returns
Our Price Match Promise
Payment Methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What fans does the Elta 149-POT-10-MI work with?
EC fans with a 0-10V speed input and variable speed drives (inverters). Elta list it for their SSDL, STDL, SJMF, SLC EC, SEL EC and SPA EC fans.
What does the MI suffix mean?
MI means the minimum speed is adjustable by an internal preset.
Can the 149-POT-10-MI control an AC fan?
Not directly. It provides a speed signal rather than switching mains voltage, so ordinary AC fans need an electronic or transformer speed controller.
What is the difference between the 149-POT-10-MI and the 149-POT-10-TB?
The TB version adds a trickle and boost switch. The MI version has a single speed knob with an internal minimum speed preset.
Does the 149-POT-10-MI make the fan hum?
No. Speed is controlled by the EC motor's own electronics, so there is none of the hum some voltage controllers cause.
How is the 149-POT-10-MI wired?
To the fan's 0-10V control terminals as shown on the fan's Elta wiring diagram. The fan keeps its own mains supply.