Elta ACO Auto Changeover Panel Three Phase AC
Elta ACO Auto Changeover Panel Three Phase AC
£629.19
SKU: 149-ACO3/B

Elta ACO Auto Changeover Panel Three Phase AC

Run and standby
Auto changeover panel
Three phase AC
Out of stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model 149-ACO3/B (ACO3TO-ADS)
Brand Elta
Type Auto changeover panel, run and standby
Supply 400V 3 phase 50Hz and neutral
Fan type Three phase AC twin fan units (direct on line)
Duty share Automatic, 12 hour cycle per fan
Changeover trigger Thermal overload trip or loss of airflow (with airflow switches)
Motor protection Contactors with preset thermal overloads
Dimensions (H x W x D) 315 x 235 x 130 mm
Mounting Surface

Summary

The Elta 149-ACO3/B is an auto changeover panel for three phase AC twin fan units. It runs the duty fan and automatically changes over to the standby fan if the duty fan's thermal overload trips, or on loss of airflow where the twin fan unit has airflow switches.

This is the automatic duty share model: an internal timer gives each fan a 12 hour duty cycle so both motors wear evenly. It runs on 400V three phase 50Hz plus neutral, uses industrial contactors with thermal overloads preset to the fans, and has a power lamp, fan fail lamp and rocker switch on the fascia in a 315 x 235 x 130 mm surface mounted enclosure.

See more specification See less specification

The Elta 149-ACO3/B is an auto changeover panel for three phase AC twin fan units. It runs the duty fan and automatically changes over to the standby fan if the duty fan's thermal overload trips, or on loss of airflow where the twin fan unit has airflow switches.

This is the automatic duty share model: an internal timer gives each fan a 12 hour duty cycle so both motors wear evenly. It runs on 400V three phase 50Hz plus neutral, uses industrial contactors with thermal overloads preset to the fans, and has a power lamp, fan fail lamp and rocker switch on the fascia in a 315 x 235 x 130 mm surface mounted enclosure.

  • Run and standby
  • Auto changeover panel
  • Three phase AC

What it is best used for

Twin fan extract or supply where ventilation must keep running if one motor fails: toilet cores in offices and schools, car park and plant room extract, kitchens and residential common areas. It suits direct on line three phase twin fan units, with or without airflow switches.

It is not suitable for use with inverters, and it is for three phase AC fans; EC twin fans need an EC changeover panel. A volt free fan fail output is on the 149-ACO3/BDV version, not this model.

Why choose this over alternatives

Against wiring two fans to manual switching, the panel changes over on its own the moment a thermal overload trips or airflow is lost, and the 12 hour auto duty share keeps run hours equal so the standby fan is not left seized. Elta's datasheets list the ACO panels against their twin fan ranges, and the ACOTO panels are compatible with Elta's EFSC and ATC speed controllers.

If you need a volt free common fan fail signal for a BMS, ask us for the 149-ACO3/BDV, which adds it.

Installation notes

  • Check the panel supplied is compatible with the fan motors and that the thermal overloads are set to the motors' full load current.
  • Install in a dry sheltered position, not close to a heat source. Remove the fascia screws for access to the fixing holes and terminals.
  • Supply is 400V three phase 50Hz with neutral and earth. Wire to the ACO3TO diagram; if the twin fan unit has no airflow switches, omit connections 1 to 3 and do not link them out.
  • To test changeover, move the timer jumper to the 1 minute test position, then return it to the 12 hour position.
  • All wiring by a suitably qualified and competent person to current regulations.

Browse more twin fans or Elta controllers, or call us for help choosing the right product.

Specifications

Model 149-ACO3/B (ACO3TO-ADS)
Brand Elta
Type Auto changeover panel, run and standby
Supply 400V 3 phase 50Hz and neutral
Fan type Three phase AC twin fan units (direct on line)
Duty share Automatic, 12 hour cycle per fan
Changeover trigger Thermal overload trip or loss of airflow (with airflow switches)
Motor protection Contactors with preset thermal overloads
Dimensions (H x W x D) 315 x 235 x 130 mm
Mounting Surface
Fascia Power lamp, fan fail lamp, rocker switch
Remote enable Optional, from volt free contacts (230V ac rated)
Fan fail output Volt free, on 149-ACO3/BDV version
Inverter use Not suitable

Manuals & Guides

Product Description

The Elta 149-ACO3/B is an auto changeover panel for three phase AC twin fan units. It runs the duty fan and automatically changes over to the standby fan if the duty fan's thermal overload trips, or on loss of airflow where the twin fan unit has airflow switches.

This is the automatic duty share model: an internal timer gives each fan a 12 hour duty cycle so both motors wear evenly. It runs on 400V three phase 50Hz plus neutral, uses industrial contactors with thermal overloads preset to the fans, and has a power lamp, fan fail lamp and rocker switch on the fascia in a 315 x 235 x 130 mm surface mounted enclosure.

  • Run and standby
  • Auto changeover panel
  • Three phase AC

What it is best used for

Twin fan extract or supply where ventilation must keep running if one motor fails: toilet cores in offices and schools, car park and plant room extract, kitchens and residential common areas. It suits direct on line three phase twin fan units, with or without airflow switches.

It is not suitable for use with inverters, and it is for three phase AC fans; EC twin fans need an EC changeover panel. A volt free fan fail output is on the 149-ACO3/BDV version, not this model.

Why choose this over alternatives

Against wiring two fans to manual switching, the panel changes over on its own the moment a thermal overload trips or airflow is lost, and the 12 hour auto duty share keeps run hours equal so the standby fan is not left seized. Elta's datasheets list the ACO panels against their twin fan ranges, and the ACOTO panels are compatible with Elta's EFSC and ATC speed controllers.

If you need a volt free common fan fail signal for a BMS, ask us for the 149-ACO3/BDV, which adds it.

Installation notes

  • Check the panel supplied is compatible with the fan motors and that the thermal overloads are set to the motors' full load current.
  • Install in a dry sheltered position, not close to a heat source. Remove the fascia screws for access to the fixing holes and terminals.
  • Supply is 400V three phase 50Hz with neutral and earth. Wire to the ACO3TO diagram; if the twin fan unit has no airflow switches, omit connections 1 to 3 and do not link them out.
  • To test changeover, move the timer jumper to the 1 minute test position, then return it to the 12 hour position.
  • All wiring by a suitably qualified and competent person to current regulations.

Browse more twin fans or Elta controllers, or call us for help choosing the right product.

Specifications

Model 149-ACO3/B (ACO3TO-ADS)
Brand Elta
Type Auto changeover panel, run and standby
Supply 400V 3 phase 50Hz and neutral
Fan type Three phase AC twin fan units (direct on line)
Duty share Automatic, 12 hour cycle per fan
Changeover trigger Thermal overload trip or loss of airflow (with airflow switches)
Motor protection Contactors with preset thermal overloads
Dimensions (H x W x D) 315 x 235 x 130 mm
Mounting Surface
Fascia Power lamp, fan fail lamp, rocker switch
Remote enable Optional, from volt free contacts (230V ac rated)
Fan fail output Volt free, on 149-ACO3/BDV version
Inverter use Not suitable

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What does the Elta 149-ACO3/B do?

It runs a three phase twin fan unit as duty and standby, automatically changing to the standby fan if the duty fan's thermal overload trips or airflow is lost.

Does the 149-ACO3/B share run time between the fans?

Yes. This is the auto duty share model, with an internal timer that gives each fan a 12 hour duty cycle.

Does it need airflow switches on the fans?

No. Without airflow switches it changes over on thermal overload trip. With airflow switches fitted it also changes over on loss of airflow.

Does the 149-ACO3/B have a BMS fan fail output?

The volt free common fan fail contact is on the 149-ACO3/BDV version. Ask us if you need that model.

Can the 149-ACO3/B be used with an inverter?

No. Elta state the ACOTO panels are not suitable for use with inverters. They are compatible with Elta's EFSC and ATC speed controllers.

What supply does the 149-ACO3/B need?

400V three phase 50Hz with neutral and earth.