Elta VL125 Inline Duct Fan Single Phase AC - 125mm/5"
Suggested products
Free 14 day returns
Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.
Why choose eFans?
- Bulk pricing available
- Free help and advice
- Fast quotes, usually within the hour
- Huge range with next-day delivery
- Credit accounts available
Delivery and Warranty
Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days.
£7.95
Next Working Day Delivery
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays)
£15.95
Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95
Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95
Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95
Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95
Product Details
Specifications
Product specifications
| Model | VL125 |
| Type | Inline centrifugal duct fan |
| Duct size | 125mm |
| Max airflow | 212 m³/h |
| Static pressure | 150 Pa |
| Motor | Single phase AC, 220-240V, 2690 rpm |
| Power | 26 W (0.14 A) |
| Noise | 43 dB(A) inlet, 38 dB(A) outlet at 3m |
| IP rating | IP44 |
| Warranty | 1 Year Manufacturer |
Summary
See more specification See less specification
The Elta Versaline VL125 is an all metal inline centrifugal fan for 125mm circular ducting, moving up to 212 m³/h in free air and rated in the Elta datasheet to 150 Pa. It is built for low airflow, medium pressure systems and its compact casing suits ceiling void mounting.
The galvanised steel casing comes with integral mounting brackets and 25mm spigots for flexible or rigid duct. The single phase motor is IP44 with Class F insulation, sealed for life bearings and a non self resetting thermal cut-out, and arrives with a flying lead and UK 3 pin plug. The motor is suitable for speed control once the supplied plug is removed and it is wired into a controller. Elta give a 12 month warranty.
- 1 Phase
- AC Motor
- Up to 212 m³/h
- Speed Controllable
What it is best used for
Toilets, shower rooms and small kitchenettes on 125mm ducting. It has a similar free air volume to the VL100 and its Elta performance table runs on to 150 Pa, where the VL100 table stops at 100 Pa. At 100 Pa the two are close (112 against 119 m³/h), so choose mainly on duct size.
It is for indoor use only, and because of its non self resetting cut-out Elta say it must not be fed through a timer or from a circuit that is regularly switched on and off. For a light switch or timer run bathroom fan, choose a fan designed for intermittent switching instead.
Why choose this over alternatives
A backward curved centrifugal impeller holds its airflow against duct resistance far better than an axial in line fan of the same size, and it is non overloading and self cleaning. The all metal casing is a sturdier choice than plastic mixed flow units in plant spaces and ceiling voids.
Compared with the Elta VL100 it is rated to 150 Pa instead of 100 Pa, although at 100 Pa the VL100 moves slightly more air. If you need more air or a choice of speeds, the Elta VL150 moves up to 468 m³/h with 3 speeds.
Installation notes
- Fix the fan with the bracket set supplied. It can be mounted at any angle, but a vertical outlet needs a weatherproof cover on the ducted outlet.
- Fit at least 1m of straight duct, the same diameter as the spigots, on both the inlet and outlet. Elta recommend cushioned clamps to cut noise transmission.
- Leave a minimum of 150mm clearance between the fan and the surrounding structure.
- Plug in, or remove the plug and wire through the pre-fitted M20 gland using a 3 core HO5VV-F cable of 7 to 10mm diameter. Provide a means of isolation and do not supply it through a timer.
- If the cut-out trips, switch the power off for one minute to reset it. Inspect and clean the fan at least once every 12 months.
You'll also need
- Elta duct clamps 018-125-CLAMP sold each, available to order, ask us.
- Elta spigot silencer 068-0125-JF1 (300mm) to 068-0125-JF4 (1200mm) available to order, ask us.
- Elta backdraught damper 018-125-DAMPER and panel filter 018-0125-FILT-P available to order, ask us.
Browse more inline duct fans, commercial extractor fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | VL125 |
| Type | Inline centrifugal duct fan |
| Duct size | 125mm |
| Max airflow | 212 m³/h |
| Static pressure | 150 Pa |
| Motor | Single phase AC, 220-240V, 2690 rpm |
| Power | 26 W (0.14 A) |
| Noise | 43 dB(A) inlet, 38 dB(A) outlet at 3m |
| IP rating | IP44 |
| Warranty | 1 Year Manufacturer |
| Airflow at 100 Pa | 112 m³/h |
| Max air temperature | +50°C |
| Casing | Galvanised pressed steel |
| Impeller | Backward curved centrifugal, non overloading |
| Insulation class | Class F, non self resetting thermal cut-out |
| Electrical connection | Flying lead with UK 3 pin plug |
| Length | 202mm |
| Weight | 3.7 kg |
Manuals & Guides
Product Description
The Elta Versaline VL125 is an all metal inline centrifugal fan for 125mm circular ducting, moving up to 212 m³/h in free air and rated in the Elta datasheet to 150 Pa. It is built for low airflow, medium pressure systems and its compact casing suits ceiling void mounting.
The galvanised steel casing comes with integral mounting brackets and 25mm spigots for flexible or rigid duct. The single phase motor is IP44 with Class F insulation, sealed for life bearings and a non self resetting thermal cut-out, and arrives with a flying lead and UK 3 pin plug. The motor is suitable for speed control once the supplied plug is removed and it is wired into a controller. Elta give a 12 month warranty.
- 1 Phase
- AC Motor
- Up to 212 m³/h
- Speed Controllable
What it is best used for
Toilets, shower rooms and small kitchenettes on 125mm ducting. It has a similar free air volume to the VL100 and its Elta performance table runs on to 150 Pa, where the VL100 table stops at 100 Pa. At 100 Pa the two are close (112 against 119 m³/h), so choose mainly on duct size.
It is for indoor use only, and because of its non self resetting cut-out Elta say it must not be fed through a timer or from a circuit that is regularly switched on and off. For a light switch or timer run bathroom fan, choose a fan designed for intermittent switching instead.
Why choose this over alternatives
A backward curved centrifugal impeller holds its airflow against duct resistance far better than an axial in line fan of the same size, and it is non overloading and self cleaning. The all metal casing is a sturdier choice than plastic mixed flow units in plant spaces and ceiling voids.
Compared with the Elta VL100 it is rated to 150 Pa instead of 100 Pa, although at 100 Pa the VL100 moves slightly more air. If you need more air or a choice of speeds, the Elta VL150 moves up to 468 m³/h with 3 speeds.
Installation notes
- Fix the fan with the bracket set supplied. It can be mounted at any angle, but a vertical outlet needs a weatherproof cover on the ducted outlet.
- Fit at least 1m of straight duct, the same diameter as the spigots, on both the inlet and outlet. Elta recommend cushioned clamps to cut noise transmission.
- Leave a minimum of 150mm clearance between the fan and the surrounding structure.
- Plug in, or remove the plug and wire through the pre-fitted M20 gland using a 3 core HO5VV-F cable of 7 to 10mm diameter. Provide a means of isolation and do not supply it through a timer.
- If the cut-out trips, switch the power off for one minute to reset it. Inspect and clean the fan at least once every 12 months.
You'll also need
- Elta duct clamps 018-125-CLAMP sold each, available to order, ask us.
- Elta spigot silencer 068-0125-JF1 (300mm) to 068-0125-JF4 (1200mm) available to order, ask us.
- Elta backdraught damper 018-125-DAMPER and panel filter 018-0125-FILT-P available to order, ask us.
Browse more inline duct fans, commercial extractor fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | VL125 |
| Type | Inline centrifugal duct fan |
| Duct size | 125mm |
| Max airflow | 212 m³/h |
| Static pressure | 150 Pa |
| Motor | Single phase AC, 220-240V, 2690 rpm |
| Power | 26 W (0.14 A) |
| Noise | 43 dB(A) inlet, 38 dB(A) outlet at 3m |
| IP rating | IP44 |
| Warranty | 1 Year Manufacturer |
| Airflow at 100 Pa | 112 m³/h |
| Max air temperature | +50°C |
| Casing | Galvanised pressed steel |
| Impeller | Backward curved centrifugal, non overloading |
| Insulation class | Class F, non self resetting thermal cut-out |
| Electrical connection | Flying lead with UK 3 pin plug |
| Length | 202mm |
| Weight | 3.7 kg |
Manuals & Guides
Delivery & Returns
Our Price Match Promise
Payment Methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What size duct does the Elta VL125 fit?
125mm circular duct. The fan has 25mm long spigots that push straight into flexible or rigid duct.
How much air does the VL125 move?
Up to 212 m³/h in free air and about 112 m³/h at 100 Pa. The Elta table goes up to 150 Pa for this size.
Can the VL125 be speed controlled?
Yes. Elta rate the motor as suitable for speed control. Remove the supplied plug and wire it into a suitable controller, and ask us if you need help choosing one.
Can it be switched on and off by a light switch or timer?
No. Elta fit a non self resetting thermal cut-out and say the fan must not be supplied through a timer or a circuit that is regularly switched on and off. It suits continuous or manually controlled duty.
Can it be mounted vertically?
Yes, at any angle using the supplied bracket set. If the outlet points up, fit a weatherproof cover on the ducted outlet.
How noisy is the VL125?
Elta quote 43 dB(A) on the inlet and 38 dB(A) on the outlet at 3m. Spigot silencers from 300mm to 1200mm long are available if it serves a quiet room.