Elta Jetflow SJMF 125 Inline Mixed Flow Fan Single Phase EC - 125mm
Elta Jetflow SJMF 125 Inline Mixed Flow Fan Single Phase EC - 125mm
£226.06
SKU: SJMF125

Elta Jetflow SJMF 125 Inline Mixed Flow Fan Single Phase EC - 125mm

1 Phase
EC Motor
Up to 288 m³/h
Estimated delivery
8 in stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model SJMF125
Type Inline mixed flow circular duct fan
Duct size 125mm
Max airflow 288 m³/h
Static pressure 200 Pa
Motor Single phase EC, 220 to 240V 50/60Hz, 5000 rpm
Power 0.027 kW (0.26 A peak)
Noise 47 dB(A) inlet, 48 dB(A) outlet at 3m
IP rating IPX4 motor
Warranty 2 Year Manufacturer

Summary

The Elta Jetflow SJMF125 is a 125mm inline mixed flow circular duct fan with a single phase EC motor, moving up to 288 m³/h in free air and 169 m³/h against 200 Pa. Its jet design double mixed flow impeller is driven directly by a brushless EC motor running at 5000 rpm, absorbing 0.027 kW at full speed.

The IPX4 motor has sealed for life heavy duty NWB bearings and is rated for air up to 60°C. It arrives with a 1.5m mains lead and UK 3 pin plug (3A fuse) for fixed speed running, plus a detachable 5m jack lead for a potentiometer, 0-10V or PWM speed signal. Elta give a 24 month warranty.

See more specification See less specification

The Elta Jetflow SJMF125 is a 125mm inline mixed flow circular duct fan with a single phase EC motor, moving up to 288 m³/h in free air and 169 m³/h against 200 Pa. Its jet design double mixed flow impeller is driven directly by a brushless EC motor running at 5000 rpm, absorbing 0.027 kW at full speed.

The IPX4 motor has sealed for life heavy duty NWB bearings and is rated for air up to 60°C. It arrives with a 1.5m mains lead and UK 3 pin plug (3A fuse) for fixed speed running, plus a detachable 5m jack lead for a potentiometer, 0-10V or PWM speed signal. Elta give a 24 month warranty.

  • 1 Phase
  • EC Motor
  • Up to 288 m³/h
  • Speed Controllable

What it is best used for

Small commercial extract on 125mm duct: a run of two or three WCs, a shower room, a staff kitchenette or a small meeting room in an office or school. It keeps 245 m³/h at 100 Pa and 169 m³/h at 200 Pa, so it can push through a long duct run with bends, a backdraught shutter and a grille.

At 288 m³/h free air it is not enough for a classroom or a cafe kitchen. For that, use the Elta SJMF150.

Why choose this over alternatives

Within the Jetflow range, the SJMF125 sits between the SJMF100 (241 m³/h free air) and the SJMF150. It has the same plug-in EC design as its siblings, so the choice comes down to duct size and duty: at 100 Pa this size delivers 245 m³/h for 0.027 kW.

It is supplied ready to run at fixed full speed on its fitted UK plug, and the detachable 5m jack lead lets you add an Elta 149-POT-10-MI controller, a 0-10V signal or PWM later without rewiring the mains side. Elta's SFP at full speed in free air is 0.3 W/(L/s).

Installation notes

  • The fan can be mounted at any angle. Fix it securely to a solid surface and leave access for cleaning and maintenance.
  • Connect to 125mm duct with Elta fast clamps (018-125-CLAMP) or flexible connectors so the fan can be removed later. Elta recommend silencers on the inlet and outlet in noise sensitive areas.
  • Mains connection is by the fitted 1.5m lead and UK 3 pin plug with a 3A fuse. The fan is supplied for fixed speed; for speed control, remove the 3.5mm jack plug and connect the supplied jack cable to a 149-POT-10-MI, 0-10V or PWM signal (wiring diagram 152-553).
  • Do not supply it through a timer or a regularly switched circuit: the EC motor has internal overload protection and may restart unexpectedly once it cools. Indoor use only, ambient -10°C to +60°C, not for corrosive or explosive atmospheres.
  • Locate the discharge so exhaust cannot be drawn back through the open flue of a gas or solid fuel appliance, and inspect and clean the fan at least every 12 months.

You'll also need

  • Elta EC electronic controller 149-POT-10-MI, the potentiometer controller Elta list for this fan.
  • Elta fast clamps 018-125-CLAMP (each) and backdraught damper 018-125-DAMPER, available to order, ask us.
  • Elta spigot silencers 068-0125-JF1 (300mm) to 068-0125-JF4 (1200mm), available to order, ask us.

What's in the box

  • Jetflow fan with 1.5m mains lead and UK 3 pin plug
  • Detachable 5m lead with 3.5mm jack for speed control

Browse more inline mixed flow fans, inline duct fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SJMF125
Type Inline mixed flow circular duct fan
Duct size 125mm
Max airflow 288 m³/h
Static pressure 200 Pa
Motor Single phase EC, 220 to 240V 50/60Hz, 5000 rpm
Power 0.027 kW (0.26 A peak)
Noise 47 dB(A) inlet, 48 dB(A) outlet at 3m
IP rating IPX4 motor
Warranty 2 Year Manufacturer
Max air temperature 60°C
Airflow at 100 Pa 245 m³/h
Airflow at 200 Pa 169 m³/h
Overall efficiency 42.7% at best efficiency point
Weight 1.1 kg
Impeller Jet design double mixed flow, direct drive
Bearings Sealed for life heavy duty NWB
Electrical connection 1.5m lead with UK 3 pin plug, 3A fuse
Speed control 149-POT-10-MI, 0-10V or PWM via 5m jack lead
Wiring diagram 152-553

Manuals & Guides

Product Description

The Elta Jetflow SJMF125 is a 125mm inline mixed flow circular duct fan with a single phase EC motor, moving up to 288 m³/h in free air and 169 m³/h against 200 Pa. Its jet design double mixed flow impeller is driven directly by a brushless EC motor running at 5000 rpm, absorbing 0.027 kW at full speed.

The IPX4 motor has sealed for life heavy duty NWB bearings and is rated for air up to 60°C. It arrives with a 1.5m mains lead and UK 3 pin plug (3A fuse) for fixed speed running, plus a detachable 5m jack lead for a potentiometer, 0-10V or PWM speed signal. Elta give a 24 month warranty.

  • 1 Phase
  • EC Motor
  • Up to 288 m³/h
  • Speed Controllable

What it is best used for

Small commercial extract on 125mm duct: a run of two or three WCs, a shower room, a staff kitchenette or a small meeting room in an office or school. It keeps 245 m³/h at 100 Pa and 169 m³/h at 200 Pa, so it can push through a long duct run with bends, a backdraught shutter and a grille.

At 288 m³/h free air it is not enough for a classroom or a cafe kitchen. For that, use the Elta SJMF150.

Why choose this over alternatives

Within the Jetflow range, the SJMF125 sits between the SJMF100 (241 m³/h free air) and the SJMF150. It has the same plug-in EC design as its siblings, so the choice comes down to duct size and duty: at 100 Pa this size delivers 245 m³/h for 0.027 kW.

It is supplied ready to run at fixed full speed on its fitted UK plug, and the detachable 5m jack lead lets you add an Elta 149-POT-10-MI controller, a 0-10V signal or PWM later without rewiring the mains side. Elta's SFP at full speed in free air is 0.3 W/(L/s).

Installation notes

  • The fan can be mounted at any angle. Fix it securely to a solid surface and leave access for cleaning and maintenance.
  • Connect to 125mm duct with Elta fast clamps (018-125-CLAMP) or flexible connectors so the fan can be removed later. Elta recommend silencers on the inlet and outlet in noise sensitive areas.
  • Mains connection is by the fitted 1.5m lead and UK 3 pin plug with a 3A fuse. The fan is supplied for fixed speed; for speed control, remove the 3.5mm jack plug and connect the supplied jack cable to a 149-POT-10-MI, 0-10V or PWM signal (wiring diagram 152-553).
  • Do not supply it through a timer or a regularly switched circuit: the EC motor has internal overload protection and may restart unexpectedly once it cools. Indoor use only, ambient -10°C to +60°C, not for corrosive or explosive atmospheres.
  • Locate the discharge so exhaust cannot be drawn back through the open flue of a gas or solid fuel appliance, and inspect and clean the fan at least every 12 months.

You'll also need

  • Elta EC electronic controller 149-POT-10-MI, the potentiometer controller Elta list for this fan.
  • Elta fast clamps 018-125-CLAMP (each) and backdraught damper 018-125-DAMPER, available to order, ask us.
  • Elta spigot silencers 068-0125-JF1 (300mm) to 068-0125-JF4 (1200mm), available to order, ask us.

What's in the box

  • Jetflow fan with 1.5m mains lead and UK 3 pin plug
  • Detachable 5m lead with 3.5mm jack for speed control

Browse more inline mixed flow fans, inline duct fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SJMF125
Type Inline mixed flow circular duct fan
Duct size 125mm
Max airflow 288 m³/h
Static pressure 200 Pa
Motor Single phase EC, 220 to 240V 50/60Hz, 5000 rpm
Power 0.027 kW (0.26 A peak)
Noise 47 dB(A) inlet, 48 dB(A) outlet at 3m
IP rating IPX4 motor
Warranty 2 Year Manufacturer
Max air temperature 60°C
Airflow at 100 Pa 245 m³/h
Airflow at 200 Pa 169 m³/h
Overall efficiency 42.7% at best efficiency point
Weight 1.1 kg
Impeller Jet design double mixed flow, direct drive
Bearings Sealed for life heavy duty NWB
Electrical connection 1.5m lead with UK 3 pin plug, 3A fuse
Speed control 149-POT-10-MI, 0-10V or PWM via 5m jack lead
Wiring diagram 152-553

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What duct size does the Elta SJMF125 fit?

It has 125mm circular spigots at each end. Elta recommend fast clamps or flexible connectors so it can be taken out for maintenance.

How much air does the SJMF125 move?

Up to 288 m³/h (0.08 m³/s) in free air at full speed, 245 m³/h at 100 Pa and 169 m³/h at 200 Pa, the highest pressure in Elta's table for this size.

Does the SJMF125 plug into a normal socket?

Yes. It comes with a 1.5m mains lead and a UK 3 pin plug with a 3A fuse, which also gives you a simple means of isolation. It runs single phase 220 to 240V.

How do I control the speed of the SJMF125?

Remove the 3.5mm jack plug and connect the supplied 5m jack lead to an Elta 149-POT-10-MI controller, a 0-10V signal from a BMS or a PWM signal. It works from a 2V control signal upwards.

How noisy is the SJMF125?

Elta quote 47 dB(A) inlet and 48 dB(A) outlet at 3m at full speed. Spigot silencers from 300 to 1200mm long are available to bring that down.

Can the SJMF125 be mounted vertically?

Yes. Elta state the fan can be mounted at any angle, as long as it is securely supported and accessible for maintenance.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently viewed