Elta Turboflow TF500 Contra Rotating Axial Flow Fan Single Phase AC - 500mm
Elta Turboflow TF500 Contra Rotating Axial Flow Fan Single Phase AC - 500mm
£1,583.99
SKU: TF500/4-1AC

Elta Turboflow TF500 Contra Rotating Axial Flow Fan Single Phase AC - 500mm

1 Phase
AC Motor
Up to 8222 m³/h
Exc VAT
Out of stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model TF500/4-1AC
Type Two stage contra-rotating axial flow fan
Diameter 500mm
Max airflow 8222 m³/h
Static pressure 300 Pa
Motor Single phase AC, 220-240V, 4 pole, 1465 rpm
Power 0.88 kW (3.94 A)
Noise 64 dB(A) inlet, 64 dB(A) outlet at 3m
Terminal box IP55, mounted on the casing
Warranty 1 Year Manufacturer

Summary

The Elta Turboflow TF500/4-1AC is a 500mm two stage contra-rotating axial flow fan for higher pressure duct systems. It moves up to 8222 m³/h in free air and the Elta datasheet shows it still delivering 5450 m³/h at 300 Pa, all inside a compact cased unit.

Both motors are airstream rated single phase induction motors with sealed for life bearings, wired through a weatherproofed cable to an IP55 terminal box on the outside of the casing. The casing is heavy gauge steel, hot dip galvanised, it suits internal or external installation and carries a 12 month Elta warranty.

See more specification See less specification

The Elta Turboflow TF500/4-1AC is a 500mm two stage contra-rotating axial flow fan for higher pressure duct systems. It moves up to 8222 m³/h in free air and the Elta datasheet shows it still delivering 5450 m³/h at 300 Pa, all inside a compact cased unit.

Both motors are airstream rated single phase induction motors with sealed for life bearings, wired through a weatherproofed cable to an IP55 terminal box on the outside of the casing. The casing is heavy gauge steel, hot dip galvanised, it suits internal or external installation and carries a 12 month Elta warranty.

  • 1 Phase
  • AC Motor
  • Up to 8222 m³/h
  • Speed Controllable

What it is best used for

A step up for 500mm ductwork in sports centres, gymnasiums, commercial kitchens with longer duct runs, warehousing and stores. It holds about 6541 m³/h at 200 Pa, so it suits systems where a single stage cased axial of the same size would stall.

It is not suitable for corrosive or explosive atmospheres, and at 64 dB(A) inlet at 3m it is not a quiet fan, so noise sensitive areas will need Elta flanged silencers. If speed control is needed in an ambient above 50°C, run it at fixed speed or look at a three phase model.

Why choose this over alternatives

Two contra-rotating impellers in series let the TF500 develop far more pressure than a single stage cased axial of the same 500mm diameter, without moving up to a bulkier centrifugal box. The impellers are adjustable pitch aerofoils in pressure die cast aluminium, and Elta quote around 7% better efficiency from the increased blade chord and twist.

Need more air? The Elta TF560 moves up to 10577 m³/h (about 8842 m³/h at 200 Pa) on 560mm ductwork. Three phase versions of the Turboflow range are also made, so ask us if a three phase supply is available.

Installation notes

  • The fan can be mounted at any angle. Make sure it is adequately supported and leave easy access to the casing and the IP55 terminal box for maintenance.
  • Wire to Elta diagram 152-502. For speed control the link between U1 and Z2 is removed and the controller wired in. Fit a means of electrical isolation, and Elta recommend a starter with overload protection.
  • Locate the discharge so exhaust air cannot be drawn back through the open flue of a gas or other fuel burning appliance.
  • At first start up check that both impellers turn the right way, the airflow direction is correct and the current does not exceed the nameplate rating.
  • Inspect and clean the motor, blades and guards at least once every 12 months. Bearings are sealed for life.

You'll also need

  • Elta matching flanges 500mm (061B-0500) for bolting the fan to flanged ductwork, sold each.
  • Elta 149-TC110 transformer speed controller the controller Elta list for this fan, available to order, ask us.
  • Elta flexible connector 063-0500-MAN150 and AV mounts 062-003 to stop vibration reaching the ductwork, available to order, ask us.
  • Elta ancillary pack APK500SI/003 (flexible connections, matching flanges, AV mounts and mounting feet) available to order, ask us.

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model TF500/4-1AC
Type Two stage contra-rotating axial flow fan
Diameter 500mm
Max airflow 8222 m³/h
Static pressure 300 Pa
Motor Single phase AC, 220-240V, 4 pole, 1465 rpm
Power 0.88 kW (3.94 A)
Noise 64 dB(A) inlet, 64 dB(A) outlet at 3m
Terminal box IP55, mounted on the casing
Warranty 1 Year Manufacturer
Airflow at 200 Pa 6541 m³/h
Airflow at 300 Pa 5450 m³/h
Operating temperature -20°C to +70°C fixed speed, up to +50°C speed controlled
Impellers Adjustable pitch aerofoil, pressure die cast aluminium
Casing Heavy gauge steel, hot dip galvanised
Overall length 550mm
Weight 85 kg
Efficiency at best point 56.7% (FMEG 63)
Speed controller 149-TC110
Wiring diagram 152-502

Manuals & Guides

Product Description

The Elta Turboflow TF500/4-1AC is a 500mm two stage contra-rotating axial flow fan for higher pressure duct systems. It moves up to 8222 m³/h in free air and the Elta datasheet shows it still delivering 5450 m³/h at 300 Pa, all inside a compact cased unit.

Both motors are airstream rated single phase induction motors with sealed for life bearings, wired through a weatherproofed cable to an IP55 terminal box on the outside of the casing. The casing is heavy gauge steel, hot dip galvanised, it suits internal or external installation and carries a 12 month Elta warranty.

  • 1 Phase
  • AC Motor
  • Up to 8222 m³/h
  • Speed Controllable

What it is best used for

A step up for 500mm ductwork in sports centres, gymnasiums, commercial kitchens with longer duct runs, warehousing and stores. It holds about 6541 m³/h at 200 Pa, so it suits systems where a single stage cased axial of the same size would stall.

It is not suitable for corrosive or explosive atmospheres, and at 64 dB(A) inlet at 3m it is not a quiet fan, so noise sensitive areas will need Elta flanged silencers. If speed control is needed in an ambient above 50°C, run it at fixed speed or look at a three phase model.

Why choose this over alternatives

Two contra-rotating impellers in series let the TF500 develop far more pressure than a single stage cased axial of the same 500mm diameter, without moving up to a bulkier centrifugal box. The impellers are adjustable pitch aerofoils in pressure die cast aluminium, and Elta quote around 7% better efficiency from the increased blade chord and twist.

Need more air? The Elta TF560 moves up to 10577 m³/h (about 8842 m³/h at 200 Pa) on 560mm ductwork. Three phase versions of the Turboflow range are also made, so ask us if a three phase supply is available.

Installation notes

  • The fan can be mounted at any angle. Make sure it is adequately supported and leave easy access to the casing and the IP55 terminal box for maintenance.
  • Wire to Elta diagram 152-502. For speed control the link between U1 and Z2 is removed and the controller wired in. Fit a means of electrical isolation, and Elta recommend a starter with overload protection.
  • Locate the discharge so exhaust air cannot be drawn back through the open flue of a gas or other fuel burning appliance.
  • At first start up check that both impellers turn the right way, the airflow direction is correct and the current does not exceed the nameplate rating.
  • Inspect and clean the motor, blades and guards at least once every 12 months. Bearings are sealed for life.

You'll also need

  • Elta matching flanges 500mm (061B-0500) for bolting the fan to flanged ductwork, sold each.
  • Elta 149-TC110 transformer speed controller the controller Elta list for this fan, available to order, ask us.
  • Elta flexible connector 063-0500-MAN150 and AV mounts 062-003 to stop vibration reaching the ductwork, available to order, ask us.
  • Elta ancillary pack APK500SI/003 (flexible connections, matching flanges, AV mounts and mounting feet) available to order, ask us.

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model TF500/4-1AC
Type Two stage contra-rotating axial flow fan
Diameter 500mm
Max airflow 8222 m³/h
Static pressure 300 Pa
Motor Single phase AC, 220-240V, 4 pole, 1465 rpm
Power 0.88 kW (3.94 A)
Noise 64 dB(A) inlet, 64 dB(A) outlet at 3m
Terminal box IP55, mounted on the casing
Warranty 1 Year Manufacturer
Airflow at 200 Pa 6541 m³/h
Airflow at 300 Pa 5450 m³/h
Operating temperature -20°C to +70°C fixed speed, up to +50°C speed controlled
Impellers Adjustable pitch aerofoil, pressure die cast aluminium
Casing Heavy gauge steel, hot dip galvanised
Overall length 550mm
Weight 85 kg
Efficiency at best point 56.7% (FMEG 63)
Speed controller 149-TC110
Wiring diagram 152-502

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What is a contra-rotating fan and why does the TF500 have two stages?

It has two impellers, one behind the other, turning in opposite directions. The second stage recovers the swirl from the first, so the TF500 reaches 300 Pa in the Elta datasheet table where a single stage cased axial of the same 500mm size would run out of pressure.

How much air does the Turboflow TF500 move?

Up to 8222 m³/h in free air, about 6541 m³/h at 200 Pa and 5450 m³/h at 300 Pa. Send us your system resistance and we will confirm the duty point.

Can the TF500 be speed controlled?

Yes. Elta list the 149-TC110 transformer controller for this fan. Speed controlled, the fan is rated for ambients up to +50°C rather than +70°C at fixed speed.

Can the TF500 be installed outside?

Yes. Elta rate the Turboflow for internal or external use. The motors are wired via a weatherproofed cable to an IP55 terminal box on the outside of the casing.

Can it be mounted vertically?

Yes. The motors have sealed for life ball bearings, so the fan can be mounted at any angle as long as it is properly supported.

How do I choose between the TF450, TF500, TF560 and TF630?

Match the fan to your duct size and duty. In free air they move 7452, 8222, 10577 and 16560 m³/h. The TF450 and TF500 are rated to 300 Pa and the TF560 and TF630 to 400 Pa in the Elta table. Send us your airflow and pressure if you are between sizes.