Elta STDL500-1EC-R Twinflow Centrifugal Box Fan Single Phase EC - 500mm (rectangular spigots)
Suggested products
Free 14 day returns
Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.
Why choose eFans?
- Bulk pricing available
- Free help and advice
- Fast quotes, usually within the hour
- Huge range with next-day delivery
- Credit accounts available
Delivery and Warranty
Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days.
£7.95
Next Working Day Delivery
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays)
£15.95
Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95
Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95
Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95
Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95
Product Details
Specifications
Product specifications
| Model | STDL500-1EC-R |
| Type | Twin fan duty/standby centrifugal box fan, EC |
| Duct connection | 498 x 598mm rectangular spigots |
| Max airflow | 5508 m³/h |
| Static pressure | 500 Pa |
| Motor | Twin EC, 1 phase 220-240V 50/60Hz, 1305 rpm |
| Power | 0.715 kW input at best efficiency, 3.70 A peak |
| Noise | 54 dB(A) inlet, 55 dB(A) outlet, 38 dB(A) breakout at 3m |
| IP rating | IP44 motors |
| Warranty | 1 Year Manufacturer |
Summary
See more specification See less specification
The Elta STDL500-1EC-R is a Twinflow duty/standby centrifugal box fan for 500mm duct systems, with rectangular spigots sized 498 x 598mm. Two backward curved fans sit side by side in one acoustically lined case: one runs, the other waits on standby. At full speed it moves up to 5508 m³/h free air, about 4968 m³/h at 100 Pa, and still delivers 1753 m³/h against 500 Pa.
Each fan has an IP44 EC external rotor motor (220 to 240V single phase, 50/60Hz) with sealed for life bearings, and the case is 1.2mm galvanised mild steel. An auto changeover panel (149-ACO1/EDV) is fitted as standard, switching to the standby fan if the duty fan fails and sharing run hours between the two. Speed is set by the built in commissioning potentiometer or a 0-10V signal, and Elta give a 12 month (1 year) manufacturer warranty.
- 1 Phase
- EC Motor
- Up to 5508 m³/h
- Speed Controllable
What it is best used for
The largest single phase STDL, for warehousing, industrial units, factories and large office or school systems on 500mm ducting where three phase is not available. It moves 5508 m³/h free air and about 4284 m³/h at 200 Pa.
At 132 kg it needs proper structural support. If a three phase supply is available, the STDL500-3EC moves more air at every pressure, about 3373 m³/h at 500 Pa against 1753 m³/h here. Not for corrosive, explosive or above +60°C air.
Why choose this over alternatives
The point of a twin fan is resilience. A single fan such as the Elta SSDL500-1EC-R Singleflow moves more air in the same duct size (5814 m³/h free air against 5508 m³/h here, and 2192 m³/h at 500 Pa against 1753 m³/h), but when its motor fails the extract stops until someone replaces it. The STDL500-1EC-R keeps running on its standby fan, the panel gives normally open fail and run contacts for a BMS or alarm, and the duty share means neither motor does all the hours. Choose it for windowless toilets, risers and any system where a dead fan means a complaint or a breach of the ventilation design; choose the Singleflow where a short outage is acceptable.
This model has rectangular spigots (498 x 598mm). If your ductwork is round, the Elta STDL500-1EC is the same fan with 500mm circular spigots. The Elta STDL500-3EC-R is the three phase version of the same size, with 6264 m³/h free air.
Installation notes
- Mount the fan horizontally only. Elta show it fixed directly to circular or rectangular duct, inverted, on AV mounts or hung from drop rods, and leave access for maintenance.
- Bring the 220 to 240V single phase, 50/60Hz supply to the terminals of the fitted auto changeover panel and provide a local means of isolation. Wiring diagram 152-717 applies.
- Set the maximum speed on the 149-CD-POT commissioning board. For external control from a potentiometer, the 149-POT-10-MI or a 0-10V BMS signal, remove the jumper and connect to terminals ST1; the board setting then caps the top speed.
- The panel's test jumper shortens the duty share switching time from 12 hours to 1 minute, so you can prove the changeover works at commissioning.
- Disconnect the EC fans before any insulation resistance testing. The electronics can be damaged and this is not covered by warranty.
You'll also need
- Elta EC Electronic Controller 149-POT-10-MI for remote manual speed control.
- Elta AV mounts 062-SEL05 available to order, ask us.
What's in the box
- Twin fan STDL unit
- Auto changeover panel 149-ACO1/EDV, fitted
- 149-CD-POT commissioning control, fitted
Browse more commercial box fans, twin fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | STDL500-1EC-R |
| Type | Twin fan duty/standby centrifugal box fan, EC |
| Duct connection | 498 x 598mm rectangular spigots |
| Max airflow | 5508 m³/h |
| Static pressure | 500 Pa |
| Motor | Twin EC, 1 phase 220-240V 50/60Hz, 1305 rpm |
| Power | 0.715 kW input at best efficiency, 3.70 A peak |
| Noise | 54 dB(A) inlet, 55 dB(A) outlet, 38 dB(A) breakout at 3m |
| IP rating | IP44 motors |
| Warranty | 1 Year Manufacturer |
| Changeover control | Auto changeover panel 149-ACO1/EDV, fitted |
| Speed control | 149-CD-POT commissioning potentiometer, 0-10V external input |
| Airflow at 100 Pa | 4968 m³/h |
| Airflow at 200 Pa | 4284 m³/h |
| Overall efficiency | 47.0% at best efficiency point |
| Casing | 1.2mm galvanised mild steel, acoustically lined |
| Mounting | Horizontal only |
| Ambient temperature | -20°C to +60°C, up to 90% RH |
| Weight | 132 kg |
Manuals & Guides
Product Description
The Elta STDL500-1EC-R is a Twinflow duty/standby centrifugal box fan for 500mm duct systems, with rectangular spigots sized 498 x 598mm. Two backward curved fans sit side by side in one acoustically lined case: one runs, the other waits on standby. At full speed it moves up to 5508 m³/h free air, about 4968 m³/h at 100 Pa, and still delivers 1753 m³/h against 500 Pa.
Each fan has an IP44 EC external rotor motor (220 to 240V single phase, 50/60Hz) with sealed for life bearings, and the case is 1.2mm galvanised mild steel. An auto changeover panel (149-ACO1/EDV) is fitted as standard, switching to the standby fan if the duty fan fails and sharing run hours between the two. Speed is set by the built in commissioning potentiometer or a 0-10V signal, and Elta give a 12 month (1 year) manufacturer warranty.
- 1 Phase
- EC Motor
- Up to 5508 m³/h
- Speed Controllable
What it is best used for
The largest single phase STDL, for warehousing, industrial units, factories and large office or school systems on 500mm ducting where three phase is not available. It moves 5508 m³/h free air and about 4284 m³/h at 200 Pa.
At 132 kg it needs proper structural support. If a three phase supply is available, the STDL500-3EC moves more air at every pressure, about 3373 m³/h at 500 Pa against 1753 m³/h here. Not for corrosive, explosive or above +60°C air.
Why choose this over alternatives
The point of a twin fan is resilience. A single fan such as the Elta SSDL500-1EC-R Singleflow moves more air in the same duct size (5814 m³/h free air against 5508 m³/h here, and 2192 m³/h at 500 Pa against 1753 m³/h), but when its motor fails the extract stops until someone replaces it. The STDL500-1EC-R keeps running on its standby fan, the panel gives normally open fail and run contacts for a BMS or alarm, and the duty share means neither motor does all the hours. Choose it for windowless toilets, risers and any system where a dead fan means a complaint or a breach of the ventilation design; choose the Singleflow where a short outage is acceptable.
This model has rectangular spigots (498 x 598mm). If your ductwork is round, the Elta STDL500-1EC is the same fan with 500mm circular spigots. The Elta STDL500-3EC-R is the three phase version of the same size, with 6264 m³/h free air.
Installation notes
- Mount the fan horizontally only. Elta show it fixed directly to circular or rectangular duct, inverted, on AV mounts or hung from drop rods, and leave access for maintenance.
- Bring the 220 to 240V single phase, 50/60Hz supply to the terminals of the fitted auto changeover panel and provide a local means of isolation. Wiring diagram 152-717 applies.
- Set the maximum speed on the 149-CD-POT commissioning board. For external control from a potentiometer, the 149-POT-10-MI or a 0-10V BMS signal, remove the jumper and connect to terminals ST1; the board setting then caps the top speed.
- The panel's test jumper shortens the duty share switching time from 12 hours to 1 minute, so you can prove the changeover works at commissioning.
- Disconnect the EC fans before any insulation resistance testing. The electronics can be damaged and this is not covered by warranty.
You'll also need
- Elta EC Electronic Controller 149-POT-10-MI for remote manual speed control.
- Elta AV mounts 062-SEL05 available to order, ask us.
What's in the box
- Twin fan STDL unit
- Auto changeover panel 149-ACO1/EDV, fitted
- 149-CD-POT commissioning control, fitted
Browse more commercial box fans, twin fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | STDL500-1EC-R |
| Type | Twin fan duty/standby centrifugal box fan, EC |
| Duct connection | 498 x 598mm rectangular spigots |
| Max airflow | 5508 m³/h |
| Static pressure | 500 Pa |
| Motor | Twin EC, 1 phase 220-240V 50/60Hz, 1305 rpm |
| Power | 0.715 kW input at best efficiency, 3.70 A peak |
| Noise | 54 dB(A) inlet, 55 dB(A) outlet, 38 dB(A) breakout at 3m |
| IP rating | IP44 motors |
| Warranty | 1 Year Manufacturer |
| Changeover control | Auto changeover panel 149-ACO1/EDV, fitted |
| Speed control | 149-CD-POT commissioning potentiometer, 0-10V external input |
| Airflow at 100 Pa | 4968 m³/h |
| Airflow at 200 Pa | 4284 m³/h |
| Overall efficiency | 47.0% at best efficiency point |
| Casing | 1.2mm galvanised mild steel, acoustically lined |
| Mounting | Horizontal only |
| Ambient temperature | -20°C to +60°C, up to 90% RH |
| Weight | 132 kg |
Manuals & Guides
Delivery & Returns
Our Price Match Promise
Payment Methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What does duty/standby mean on the Elta STDL500-1EC-R?
There are two fans in one case. One runs as the duty fan while the other stands by. The fitted auto changeover panel starts the standby fan automatically if the duty fan fails, and it also swaps the fans over on a timed duty share so the run hours are spread across both motors.
Do I need to buy a separate changeover panel?
No. The 149-ACO1/EDV auto changeover panel comes fitted, and the mains supply connects straight to it. It provides normally open fail and run contacts so a BMS or alarm can see a fan failure.
How much air does the STDL500-1EC-R move?
Up to 5508 m³/h (1.53 m³/s) at free air on full speed, about 4968 m³/h at 100 Pa, 4284 m³/h at 200 Pa and 1753 m³/h at 500 Pa.
How do I control the fan speed?
Set a single fixed speed on the built in 149-CD-POT commissioning potentiometer, or remove its jumper and wire in the Elta 149-POT-10-MI controller or a 0-10V BMS signal. The commissioning setting then acts as the maximum speed.
What duct size does it connect to?
It has 498 x 598mm rectangular spigots. The STDL500-1EC is the version with 500mm circular spigots.
Can it be mounted vertically?
No. Elta state the STDL must be mounted horizontally. It can be fixed to the duct, inverted, set on AV mounts or hung on drop rods. It weighs 132 kg, so make sure the fixings are rated for it.