Elta SLCX355/4-3AC Revolution ATEX Long Cased Axial Fan Three Phase AC - 355mm
Elta SLCX355/4-3AC Revolution ATEX Long Cased Axial Fan Three Phase AC - 355mm
£2,007.99
SKU: SLCX355/4-3AC

Elta SLCX355/4-3AC Revolution ATEX Long Cased Axial Fan Three Phase AC - 355mm

3 Phase
AC Motor
Up to 3096 m³/h
Out of stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model SLCX355/4-3AC
Type ATEX long cased axial fan, duct mounted
Diameter 355mm
Max airflow 3096 m³/h
Static pressure 100 Pa
Motor Three phase AC, 380-415V 50Hz, 4 pole, 1360 rpm
Power 0.37 kW (1.10 A peak)
Noise 50 dB(A) inlet, 49 dB(A) outlet at 3m
ATEX marking Ex h IIB+H2 T4 Gb
Warranty 1 Year Manufacturer

Summary

The Elta SLCX355/4-3AC is a 355mm ATEX rated long cased axial fan from the Elta Revolution SLCX range, built for duct mounting in hazardous areas. It moves up to 3096 m³/h at free air and still delivers 2333 m³/h at 100 Pa, driven by a 0.37 kW 4 pole three phase motor running at 1360 rpm.

Elta mark the SLCX to Ex h IIB+H2 T4 Gb, classified for constructional safety under the 2014/34/EU directive. The casing is heavy gauge sheet steel, roll formed, welded and dip galvanised after fabrication, and the adjustable pitch aerofoil impeller has carbon filled anti-static blades on a die cast aluminium hub. It is fixed speed, direct on line, and Elta give a 12 month warranty.

See more specification See less specification

The Elta SLCX355/4-3AC is a 355mm ATEX rated long cased axial fan from the Elta Revolution SLCX range, built for duct mounting in hazardous areas. It moves up to 3096 m³/h at free air and still delivers 2333 m³/h at 100 Pa, driven by a 0.37 kW 4 pole three phase motor running at 1360 rpm.

Elta mark the SLCX to Ex h IIB+H2 T4 Gb, classified for constructional safety under the 2014/34/EU directive. The casing is heavy gauge sheet steel, roll formed, welded and dip galvanised after fabrication, and the adjustable pitch aerofoil impeller has carbon filled anti-static blades on a die cast aluminium hub. It is fixed speed, direct on line, and Elta give a 12 month warranty.

  • 3 Phase
  • AC Motor
  • Up to 3096 m³/h
  • Fixed Speed

What it is best used for

Low volume extract from small classified spaces on short duct runs: a solvent or flammable liquids store, a small forklift or standby battery charging room, a laboratory chemical store or a small pumping station dry well. At 3096 m³/h free air it suits rooms where only a modest air change rate is needed.

It runs out of pressure at 100 Pa, so it is the wrong fan for long ductwork, filters or scrubbers. For more resistance step up to the Elta SLCX400/4-3AC (150 Pa) or the 2 pole Elta SLCX400/2-3AC (400 Pa). It is not suitable for Zone 0, and the marking is for gas atmospheres only, so ask us before specifying it for a combustible dust zone. Zone classification is the responsibility of the installer or site duty holder: check the Ex h IIB+H2 T4 Gb marking against your hazardous area classification before ordering.

Why choose this over alternatives

Choose the SLCX only where the area is classified as hazardous. Its Ex h IIB+H2 T4 Gb marking, anti-static impeller blades and ATEX build are what you are paying for; the standard Elta SLC355 three phase is the non-ATEX version of a similar size for ordinary ventilation and costs considerably less, but must never be used in a zoned area.

It is the smallest and lightest fan in the SLCX range at 29 kg, with the lowest power draw (0.37 kW) and the quietest output at 50 dB(A) at 3m.

Installation notes

  • Electrical installation must comply with BS7671 and EN60079-0 and be carried out by competent persons. Provide a means of electrical isolation in the fixed wiring and wire to diagram 152-612 through the M20 cable entry, with the M6 earth stud bonded.
  • The fan can be mounted at any angle. Seal all flanges with an oil and diesel resistant silicone sealant, and fix to the 425mm flange using the 8 holes of 10mm diameter on a 395mm PCD.
  • Elta state the zone inside and outside the fan can differ by no more than one zone (for example Zone 1 inside, Zone 2 outside), except when fitted with a flexible duct connection, where there is no zone separation. It is not suitable for Zone 0.
  • It is fixed speed, direct on line. Elta must be consulted before any speed controller or inverter is used, and the controller in the ancillary pack is not ATEX rated and must be mounted outside the hazardous area.
  • At start up check rotation, airflow direction and that motor current does not exceed the nameplate. Inspect AV mounts and earth bonding every 6 months, and check impeller tip clearance every 26,000 hours or 3 years.

You'll also need

  • Elta matching flanges 350mm (061B-0350) sold each, one per duct connection
  • Elta ancillary pack APK350/002 available to order, ask us. Its controller is not ATEX rated and must be mounted outside the hazardous area.
  • Elta AV mounts 062-002 available to order, ask us
  • Elta impeller side guard 078C-0350-C available to order, ask us. Guarding is not included with the fan.

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SLCX355/4-3AC
Type ATEX long cased axial fan, duct mounted
Diameter 355mm
Max airflow 3096 m³/h
Static pressure 100 Pa
Motor Three phase AC, 380-415V 50Hz, 4 pole, 1360 rpm
Power 0.37 kW (1.10 A peak)
Noise 50 dB(A) inlet, 49 dB(A) outlet at 3m
ATEX marking Ex h IIB+H2 T4 Gb
Warranty 1 Year Manufacturer
Airflow at 100 Pa 2333 m³/h
Starting current 3.74 A, direct on line
Speed control Fixed speed, consult Elta before using a controller or inverter
Directive 2014/34/EU, not suitable for Zone 0
Ambient temperature minus 20°C up to 40°C
Impeller Adjustable pitch aerofoil, carbon filled anti-static blades, LM24 aluminium hub, balanced to ISO 14694 G6.3
Casing Heavy gauge steel, dip galvanised to BS EN ISO 1461
Casing length 375mm
Flange 425mm outside diameter, 8 holes 10mm diameter on 395mm PCD
Cable entry M20, terminal box on casing
Wiring diagram 152-612
Weight 29 kg

Manuals & Guides

Product Description

The Elta SLCX355/4-3AC is a 355mm ATEX rated long cased axial fan from the Elta Revolution SLCX range, built for duct mounting in hazardous areas. It moves up to 3096 m³/h at free air and still delivers 2333 m³/h at 100 Pa, driven by a 0.37 kW 4 pole three phase motor running at 1360 rpm.

Elta mark the SLCX to Ex h IIB+H2 T4 Gb, classified for constructional safety under the 2014/34/EU directive. The casing is heavy gauge sheet steel, roll formed, welded and dip galvanised after fabrication, and the adjustable pitch aerofoil impeller has carbon filled anti-static blades on a die cast aluminium hub. It is fixed speed, direct on line, and Elta give a 12 month warranty.

  • 3 Phase
  • AC Motor
  • Up to 3096 m³/h
  • Fixed Speed

What it is best used for

Low volume extract from small classified spaces on short duct runs: a solvent or flammable liquids store, a small forklift or standby battery charging room, a laboratory chemical store or a small pumping station dry well. At 3096 m³/h free air it suits rooms where only a modest air change rate is needed.

It runs out of pressure at 100 Pa, so it is the wrong fan for long ductwork, filters or scrubbers. For more resistance step up to the Elta SLCX400/4-3AC (150 Pa) or the 2 pole Elta SLCX400/2-3AC (400 Pa). It is not suitable for Zone 0, and the marking is for gas atmospheres only, so ask us before specifying it for a combustible dust zone. Zone classification is the responsibility of the installer or site duty holder: check the Ex h IIB+H2 T4 Gb marking against your hazardous area classification before ordering.

Why choose this over alternatives

Choose the SLCX only where the area is classified as hazardous. Its Ex h IIB+H2 T4 Gb marking, anti-static impeller blades and ATEX build are what you are paying for; the standard Elta SLC355 three phase is the non-ATEX version of a similar size for ordinary ventilation and costs considerably less, but must never be used in a zoned area.

It is the smallest and lightest fan in the SLCX range at 29 kg, with the lowest power draw (0.37 kW) and the quietest output at 50 dB(A) at 3m.

Installation notes

  • Electrical installation must comply with BS7671 and EN60079-0 and be carried out by competent persons. Provide a means of electrical isolation in the fixed wiring and wire to diagram 152-612 through the M20 cable entry, with the M6 earth stud bonded.
  • The fan can be mounted at any angle. Seal all flanges with an oil and diesel resistant silicone sealant, and fix to the 425mm flange using the 8 holes of 10mm diameter on a 395mm PCD.
  • Elta state the zone inside and outside the fan can differ by no more than one zone (for example Zone 1 inside, Zone 2 outside), except when fitted with a flexible duct connection, where there is no zone separation. It is not suitable for Zone 0.
  • It is fixed speed, direct on line. Elta must be consulted before any speed controller or inverter is used, and the controller in the ancillary pack is not ATEX rated and must be mounted outside the hazardous area.
  • At start up check rotation, airflow direction and that motor current does not exceed the nameplate. Inspect AV mounts and earth bonding every 6 months, and check impeller tip clearance every 26,000 hours or 3 years.

You'll also need

  • Elta matching flanges 350mm (061B-0350) sold each, one per duct connection
  • Elta ancillary pack APK350/002 available to order, ask us. Its controller is not ATEX rated and must be mounted outside the hazardous area.
  • Elta AV mounts 062-002 available to order, ask us
  • Elta impeller side guard 078C-0350-C available to order, ask us. Guarding is not included with the fan.

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SLCX355/4-3AC
Type ATEX long cased axial fan, duct mounted
Diameter 355mm
Max airflow 3096 m³/h
Static pressure 100 Pa
Motor Three phase AC, 380-415V 50Hz, 4 pole, 1360 rpm
Power 0.37 kW (1.10 A peak)
Noise 50 dB(A) inlet, 49 dB(A) outlet at 3m
ATEX marking Ex h IIB+H2 T4 Gb
Warranty 1 Year Manufacturer
Airflow at 100 Pa 2333 m³/h
Starting current 3.74 A, direct on line
Speed control Fixed speed, consult Elta before using a controller or inverter
Directive 2014/34/EU, not suitable for Zone 0
Ambient temperature minus 20°C up to 40°C
Impeller Adjustable pitch aerofoil, carbon filled anti-static blades, LM24 aluminium hub, balanced to ISO 14694 G6.3
Casing Heavy gauge steel, dip galvanised to BS EN ISO 1461
Casing length 375mm
Flange 425mm outside diameter, 8 holes 10mm diameter on 395mm PCD
Cable entry M20, terminal box on casing
Wiring diagram 152-612
Weight 29 kg

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What ATEX zones can the Elta SLCX355/4-3AC be used in?

It is marked Ex h IIB+H2 T4 Gb. Elta state it is not suitable for Zone 0, and the zone inside and outside the fan can differ by no more than one zone, for example Zone 1 inside and Zone 2 outside. The installer or site duty holder is responsible for zone classification, so check the marking on the label and Certificate of Conformity against your hazardous area drawing.

Which gases is the SLCX355/4-3AC certified for?

Gas group IIB plus hydrogen (IIB+H2) with temperature class T4 and equipment protection level Gb. The marking covers gas atmospheres only, so ask us before using it in a combustible dust zone.

How much air does the SLCX355/4-3AC move?

Up to 3096 m³/h (0.860 m³/s) at free air, 2333 m³/h at 100 Pa, which is the highest pressure in the Elta performance table for this model.

Can I use a speed controller with it?

It is supplied as a fixed speed, direct on line fan. Elta must be consulted before a speed controller or inverter is used, and the controller in the Elta ancillary pack is not ATEX rated and must be mounted outside the hazardous area.

What size flanges and duct does the SLCX355/4-3AC need?

It fits a 355mm duct. The flange is 425mm across with 8 holes of 10mm diameter on a 395mm PCD, the casing is 375mm long and the fan weighs 29 kg.

Can it be mounted vertically?

Yes. Elta allow mounting at any angle, for extract or supply, as long as the fan is properly supported. Wiring diagram 152-612 shows connections for both A and B flow directions, so check rotation and airflow direction at start up.