Elta SDA500/4-3EC Raptor Case Mounted Axial Fan Three Phase EC - 500mm
Elta SDA500/4-3EC Raptor Case Mounted Axial Fan Three Phase EC - 500mm
£2,111.99
SKU: SDA500/4-3EC

Elta SDA500/4-3EC Raptor Case Mounted Axial Fan Three Phase EC - 500mm

3 Phase
EC Motor
Up to 9536 m³/h
Estimated delivery
Only 1 in stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model SDA500/4-3EC
Type Cased axial fan, short case
Diameter 500mm
Max airflow 9536 m³/h
Static pressure 200 Pa
Motor Three phase EC, 380-480V 50/60Hz, 1555 rpm
Power 920 W (1.53 A peak)
Noise 59 dB(A) inlet, 58 dB(A) outlet at 3m
IP rating IP54 motor, IP55 terminal box
Warranty 1 Year Manufacturer

Summary

The Elta SDA500/4-3EC is a 500mm Raptor SDA short cased axial fan for fitting in 500mm ductwork. It moves up to 9536 m³/h in free air, 8348 m³/h at 100 Pa and still 6019 m³/h at 200 Pa, the highest pressure in Elta's published table for this model.

A three phase EC external rotor motor (380-480V 50/60Hz) with an integrated variable speed drive runs at up to 1555 rpm and draws 920 W at best efficiency (1.53 A peak), with internal electronic overload protection. Speed is set by a 0-10V signal or Elta's 149-POT-10-MI potentiometer. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP54, and Elta give a 12 month warranty.

See more specification See less specification

The Elta SDA500/4-3EC is a 500mm Raptor SDA short cased axial fan for fitting in 500mm ductwork. It moves up to 9536 m³/h in free air, 8348 m³/h at 100 Pa and still 6019 m³/h at 200 Pa, the highest pressure in Elta's published table for this model.

A three phase EC external rotor motor (380-480V 50/60Hz) with an integrated variable speed drive runs at up to 1555 rpm and draws 920 W at best efficiency (1.53 A peak), with internal electronic overload protection. Speed is set by a 0-10V signal or Elta's 149-POT-10-MI potentiometer. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP54, and Elta give a 12 month warranty.

  • 3 Phase
  • EC Motor
  • Up to 9536 m³/h
  • Speed Controllable

What it is best used for

Larger ducted duties on 500mm duct: sports halls, factory bays, warehousing, retail parks and commercial kitchens. At 50 Pa it moves 9065 m³/h, roughly 6 air changes an hour in a space of about 1510 m³.

It still gives 6019 m³/h at 200 Pa, but Elta publish no figures for it beyond that, so very high resistance systems need a mixed flow or centrifugal fan. It is not suitable for corrosive or explosive atmospheres, and the air must stay between -20°C and +70°C.

Why choose this over alternatives

There are 5 Raptor SDA models in the 500mm case, and the choice comes down to supply, noise and control. This EC version gives fully variable speed from a 0-10V signal with no separate controller needed for BMS control, and at 41.8% overall efficiency it is more efficient than any AC model in this size (the best is the SDA500/46-3AC at 34.2%). In the same size there is also the Elta SDA500/4-1AC (4 pole single phase, 8626 m³/h, 51 dB(A)), the Elta SDA500/6-1AC (6 pole single phase, 6188 m³/h, 46 dB(A)), the Elta SDA500/46-3AC (two speed three phase, 8813 m³/h, 53 dB(A)) and the Elta SDA500/4-1EC (single phase EC, 8582 m³/h, 57 dB(A)).

If you need more air, the Elta SDA630/4-3EC moves 13774 m³/h in free air. If the fan will sit in a wall or panel rather than in a duct, the Elta SPA500/4-3EC plate fan uses the same Raptor impeller and motor family on a square mounting plate.

Installation notes

  • Fit it in the duct run at any angle, securely supported, with access for maintenance. The case is 250mm long with 12 holes of 10mm on a 541mm PCD at each end for Elta matching flanges 061A-0500-C, and mounting feet 060A-0500-C are available.
  • Wire to Elta diagram 152-MOEA03K3 through the fitted terminal box (21mm cable entry). For variable speed connect a 0-10V signal or the 149-POT-10-MI potentiometer to the 10V, E1 and GND terminals.
  • Disconnect the fan before any insulation resistance testing. Elta warn this can damage the EC electronics and is not covered by warranty.
  • Fit a local means of isolation, and site the discharge so exhaust cannot be drawn back into a room through the open flue of a gas or fuel burning appliance.
  • At first start check rotation, airflow direction and that the running current is within the rating plate. Inspect and clean the blades and guards at least every 12 months.

You'll also need

  • Elta EC electronic controller 149-POT-10-MI (the potentiometer controller Elta list for every EC Raptor SDA)
  • Elta ancillary pack APK500SCD/002 (flexible connections, matching flanges, anti-vibration mounts and mounting feet) available to order, ask us

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SDA500/4-3EC
Type Cased axial fan, short case
Diameter 500mm
Max airflow 9536 m³/h
Static pressure 200 Pa
Motor Three phase EC, 380-480V 50/60Hz, 1555 rpm
Power 920 W (1.53 A peak)
Noise 59 dB(A) inlet, 58 dB(A) outlet at 3m
IP rating IP54 motor, IP55 terminal box
Warranty 1 Year Manufacturer
Airflow at 50 Pa 9065 m³/h
Airflow at 100 Pa 8348 m³/h
Airflow at 150 Pa 7412 m³/h
Airflow at 5V control signal 4435 m³/h, 43 dB(A) at 3m
Speed control Integrated variable speed drive, 0-10V or potentiometer
Overall efficiency 41.8% at best efficiency point
FMEG 47
Case 250mm long, 503mm internal diameter, 575mm flange diameter
Flange fixings 12 holes 10mm on 541mm PCD
Impeller Ziehl-Abegg FE2owlet aerofoil with serrated trailing edges
Finish Powder coated mild steel, RAL 7045
Operating temperature -20°C to +70°C, up to 95% RH
Weight 18 kg
Wiring diagram 152-MOEA03K3

Manuals & Guides

Product Description

The Elta SDA500/4-3EC is a 500mm Raptor SDA short cased axial fan for fitting in 500mm ductwork. It moves up to 9536 m³/h in free air, 8348 m³/h at 100 Pa and still 6019 m³/h at 200 Pa, the highest pressure in Elta's published table for this model.

A three phase EC external rotor motor (380-480V 50/60Hz) with an integrated variable speed drive runs at up to 1555 rpm and draws 920 W at best efficiency (1.53 A peak), with internal electronic overload protection. Speed is set by a 0-10V signal or Elta's 149-POT-10-MI potentiometer. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP54, and Elta give a 12 month warranty.

  • 3 Phase
  • EC Motor
  • Up to 9536 m³/h
  • Speed Controllable

What it is best used for

Larger ducted duties on 500mm duct: sports halls, factory bays, warehousing, retail parks and commercial kitchens. At 50 Pa it moves 9065 m³/h, roughly 6 air changes an hour in a space of about 1510 m³.

It still gives 6019 m³/h at 200 Pa, but Elta publish no figures for it beyond that, so very high resistance systems need a mixed flow or centrifugal fan. It is not suitable for corrosive or explosive atmospheres, and the air must stay between -20°C and +70°C.

Why choose this over alternatives

There are 5 Raptor SDA models in the 500mm case, and the choice comes down to supply, noise and control. This EC version gives fully variable speed from a 0-10V signal with no separate controller needed for BMS control, and at 41.8% overall efficiency it is more efficient than any AC model in this size (the best is the SDA500/46-3AC at 34.2%). In the same size there is also the Elta SDA500/4-1AC (4 pole single phase, 8626 m³/h, 51 dB(A)), the Elta SDA500/6-1AC (6 pole single phase, 6188 m³/h, 46 dB(A)), the Elta SDA500/46-3AC (two speed three phase, 8813 m³/h, 53 dB(A)) and the Elta SDA500/4-1EC (single phase EC, 8582 m³/h, 57 dB(A)).

If you need more air, the Elta SDA630/4-3EC moves 13774 m³/h in free air. If the fan will sit in a wall or panel rather than in a duct, the Elta SPA500/4-3EC plate fan uses the same Raptor impeller and motor family on a square mounting plate.

Installation notes

  • Fit it in the duct run at any angle, securely supported, with access for maintenance. The case is 250mm long with 12 holes of 10mm on a 541mm PCD at each end for Elta matching flanges 061A-0500-C, and mounting feet 060A-0500-C are available.
  • Wire to Elta diagram 152-MOEA03K3 through the fitted terminal box (21mm cable entry). For variable speed connect a 0-10V signal or the 149-POT-10-MI potentiometer to the 10V, E1 and GND terminals.
  • Disconnect the fan before any insulation resistance testing. Elta warn this can damage the EC electronics and is not covered by warranty.
  • Fit a local means of isolation, and site the discharge so exhaust cannot be drawn back into a room through the open flue of a gas or fuel burning appliance.
  • At first start check rotation, airflow direction and that the running current is within the rating plate. Inspect and clean the blades and guards at least every 12 months.

You'll also need

  • Elta EC electronic controller 149-POT-10-MI (the potentiometer controller Elta list for every EC Raptor SDA)
  • Elta ancillary pack APK500SCD/002 (flexible connections, matching flanges, anti-vibration mounts and mounting feet) available to order, ask us

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SDA500/4-3EC
Type Cased axial fan, short case
Diameter 500mm
Max airflow 9536 m³/h
Static pressure 200 Pa
Motor Three phase EC, 380-480V 50/60Hz, 1555 rpm
Power 920 W (1.53 A peak)
Noise 59 dB(A) inlet, 58 dB(A) outlet at 3m
IP rating IP54 motor, IP55 terminal box
Warranty 1 Year Manufacturer
Airflow at 50 Pa 9065 m³/h
Airflow at 100 Pa 8348 m³/h
Airflow at 150 Pa 7412 m³/h
Airflow at 5V control signal 4435 m³/h, 43 dB(A) at 3m
Speed control Integrated variable speed drive, 0-10V or potentiometer
Overall efficiency 41.8% at best efficiency point
FMEG 47
Case 250mm long, 503mm internal diameter, 575mm flange diameter
Flange fixings 12 holes 10mm on 541mm PCD
Impeller Ziehl-Abegg FE2owlet aerofoil with serrated trailing edges
Finish Powder coated mild steel, RAL 7045
Operating temperature -20°C to +70°C, up to 95% RH
Weight 18 kg
Wiring diagram 152-MOEA03K3

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

How much air does the Elta SDA500/4-3EC move?

Up to 9536 m³/h in free air, 9065 m³/h at 50 Pa, 8348 m³/h at 100 Pa and 6019 m³/h at 200 Pa.

What size duct does the SDA500/4-3EC fit?

500mm. The case has a 503mm internal diameter and 12 flange holes of 10mm on a 541mm PCD at each end, which match Elta's 061A-0500-C matching flanges.

How do I control the speed?

The motor has a built in variable speed drive. Use Elta's 149-POT-10-MI potentiometer, which we stock, or a 0-10V signal from a BMS. At a 5V signal it still moves 4435 m³/h at 43 dB(A).

How noisy is it?

Elta quote 59 dB(A) at the inlet and 58 dB(A) at the outlet at 3m at full speed. Matching 1D and 2D flanged silencers (068-0500) are available to order if you need it quieter.

What power supply does it need?

A three phase 380-480V 50/60Hz supply. Peak current is 1.53 A at 400V, and Elta wiring diagram 152-MOEA03K3 applies. It must be wired by a qualified electrician with a local isolator.

Can it be mounted vertically or outside the building?

It can be mounted at any angle, horizontal or vertical. The motor is IP54 with an IP55 terminal box and the fan handles air from -20°C to +70°C, but it is designed to sit in ductwork rather than be exposed to the weather; on an external wall fit a weather cowl such as Elta SWC45/50.