Elta SDA350/4-1AC Raptor Case Mounted Axial Fan Single Phase AC - 350mm
Elta SDA350/4-1AC Raptor Case Mounted Axial Fan Single Phase AC - 350mm
£633.59
SKU: SDA350/4-1AC

Elta SDA350/4-1AC Raptor Case Mounted Axial Fan Single Phase AC - 350mm

1 Phase
AC Motor
Up to 2570 m³/h
Estimated delivery
Only 1 in stock
Not sure what you need? Email the teamhello@efans.co.uk
Free 14 day returns

Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.

Why choose eFans?
  • Bulk pricing available
  • Free help and advice
  • Fast quotes, usually within the hour
  • Huge range with next-day delivery
  • Credit accounts available
Delivery and Warranty

Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days. 
£7.95  

Next Working Day Delivery 
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays) 
£15.95 

Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95

Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95 

Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95

Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95 

Product Details

Specifications

Product specifications
Model SDA350/4-1AC
Type Cased axial fan, short case
Diameter 350mm
Max airflow 2570 m³/h
Static pressure 50 Pa
Motor Single phase AC, 220-240V 50Hz, 4 pole, 1075 rpm
Power 119 W (0.54 A peak)
Noise 45 dB(A) at 3m
IP rating IP44 motor, IP55 terminal box
Warranty 1 Year Manufacturer

Summary

The Elta SDA350/4-1AC is a 350mm Raptor SDA short cased axial fan for fitting in 350mm ductwork. It moves up to 2570 m³/h in free air and still 1544 m³/h at 50 Pa, the highest pressure in Elta's published table for this model.

A 4 pole single phase AC external rotor motor (220-240V 50Hz) runs at 1075 rpm and draws 119 W at best efficiency (0.54 A peak). It is insulated to Class F with integral thermal overload protection and suits speed control. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP44, and Elta give a 12 month warranty.

See more specification See less specification

The Elta SDA350/4-1AC is a 350mm Raptor SDA short cased axial fan for fitting in 350mm ductwork. It moves up to 2570 m³/h in free air and still 1544 m³/h at 50 Pa, the highest pressure in Elta's published table for this model.

A 4 pole single phase AC external rotor motor (220-240V 50Hz) runs at 1075 rpm and draws 119 W at best efficiency (0.54 A peak). It is insulated to Class F with integral thermal overload protection and suits speed control. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP44, and Elta give a 12 month warranty.

  • 1 Phase
  • AC Motor
  • Up to 2570 m³/h
  • Speed Controllable

What it is best used for

Ducted extract or supply on 350mm duct for classrooms, small retail units, squash courts and workshops where the run is short and the grilles are generous. At 50 Pa it moves 1544 m³/h, roughly 6 air changes an hour in a space of about 260 m³.

Its published curve stops at 50 Pa, so it is the wrong fan for long duct runs, filters, heater batteries or attenuators; for those a centrifugal box fan or an inline mixed flow fan holds its airflow far better. It is not suitable for corrosive or explosive atmospheres, and the air must stay between -20°C and +70°C.

Why choose this over alternatives

There are 2 Raptor SDA models in the 350mm case, and the choice comes down to supply, noise and control. This 4 pole single phase version runs from a standard 230V supply at 1075 rpm. In the same size there is also the Elta SDA350/4-1EC (single phase EC, 4316 m³/h, 57 dB(A)).

If you need more air, the Elta SDA400/4-1AC moves 3611 m³/h in free air. For a smaller duct the Elta SDA315/4-1AC gives 2185 m³/h. If the fan will sit in a wall or panel rather than in a duct, the Elta SPA350/4-1AC plate fan uses the same Raptor impeller and motor family on a square mounting plate.

Installation notes

  • Fit it in the duct run at any angle, securely supported, with access for maintenance. The case is 180mm long with 8 holes of 10mm on a 395mm PCD at each end for Elta matching flanges 061A-0350-C, and mounting feet 060A-0350-C are available.
  • Wire to Elta diagram 152-104B through the fitted IP55 terminal box (21mm cable entry), and connect the thermal cut-out leads (TB TB) into the control circuit so the motor is protected.
  • For speed control Elta list the 149-TC12 for this model; check the controller amp rating against the 0.54 A peak current.
  • Fit a local means of isolation, and site the discharge so exhaust cannot be drawn back into a room through the open flue of a gas or fuel burning appliance.
  • At first start check rotation, airflow direction and that the running current is within the rating plate. Inspect and clean the blades and guards at least every 12 months.

You'll also need

  • Elta 149-TC12 five step transformer controller available to order, ask us
  • Elta ancillary pack APK350SCD/001 (flexible connections, matching flanges, anti-vibration mounts and mounting feet) available to order, ask us

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SDA350/4-1AC
Type Cased axial fan, short case
Diameter 350mm
Max airflow 2570 m³/h
Static pressure 50 Pa
Motor Single phase AC, 220-240V 50Hz, 4 pole, 1075 rpm
Power 119 W (0.54 A peak)
Noise 45 dB(A) at 3m
IP rating IP44 motor, IP55 terminal box
Warranty 1 Year Manufacturer
Overall efficiency 24.0% at best efficiency point
FMEG Below 125W, outside ErP 327/2011 limits
Case 180mm long, 356mm internal diameter, 421mm flange diameter
Flange fixings 8 holes 10mm on 395mm PCD
Impeller Ziehl-Abegg FE2owlet aerofoil with serrated trailing edges
Finish Powder coated mild steel, RAL 7045
Operating temperature -20°C to +70°C, up to 95% RH
Weight 8 kg
Wiring diagram 152-104B

Manuals & Guides

Product Description

The Elta SDA350/4-1AC is a 350mm Raptor SDA short cased axial fan for fitting in 350mm ductwork. It moves up to 2570 m³/h in free air and still 1544 m³/h at 50 Pa, the highest pressure in Elta's published table for this model.

A 4 pole single phase AC external rotor motor (220-240V 50Hz) runs at 1075 rpm and draws 119 W at best efficiency (0.54 A peak). It is insulated to Class F with integral thermal overload protection and suits speed control. The Ziehl-Abegg FE2owlet aerofoil impeller has serrated trailing edges and winglets for lower noise, the mild steel case is powder coated in RAL 7045 with an IP55 terminal box, the motor is IP44, and Elta give a 12 month warranty.

  • 1 Phase
  • AC Motor
  • Up to 2570 m³/h
  • Speed Controllable

What it is best used for

Ducted extract or supply on 350mm duct for classrooms, small retail units, squash courts and workshops where the run is short and the grilles are generous. At 50 Pa it moves 1544 m³/h, roughly 6 air changes an hour in a space of about 260 m³.

Its published curve stops at 50 Pa, so it is the wrong fan for long duct runs, filters, heater batteries or attenuators; for those a centrifugal box fan or an inline mixed flow fan holds its airflow far better. It is not suitable for corrosive or explosive atmospheres, and the air must stay between -20°C and +70°C.

Why choose this over alternatives

There are 2 Raptor SDA models in the 350mm case, and the choice comes down to supply, noise and control. This 4 pole single phase version runs from a standard 230V supply at 1075 rpm. In the same size there is also the Elta SDA350/4-1EC (single phase EC, 4316 m³/h, 57 dB(A)).

If you need more air, the Elta SDA400/4-1AC moves 3611 m³/h in free air. For a smaller duct the Elta SDA315/4-1AC gives 2185 m³/h. If the fan will sit in a wall or panel rather than in a duct, the Elta SPA350/4-1AC plate fan uses the same Raptor impeller and motor family on a square mounting plate.

Installation notes

  • Fit it in the duct run at any angle, securely supported, with access for maintenance. The case is 180mm long with 8 holes of 10mm on a 395mm PCD at each end for Elta matching flanges 061A-0350-C, and mounting feet 060A-0350-C are available.
  • Wire to Elta diagram 152-104B through the fitted IP55 terminal box (21mm cable entry), and connect the thermal cut-out leads (TB TB) into the control circuit so the motor is protected.
  • For speed control Elta list the 149-TC12 for this model; check the controller amp rating against the 0.54 A peak current.
  • Fit a local means of isolation, and site the discharge so exhaust cannot be drawn back into a room through the open flue of a gas or fuel burning appliance.
  • At first start check rotation, airflow direction and that the running current is within the rating plate. Inspect and clean the blades and guards at least every 12 months.

You'll also need

  • Elta 149-TC12 five step transformer controller available to order, ask us
  • Elta ancillary pack APK350SCD/001 (flexible connections, matching flanges, anti-vibration mounts and mounting feet) available to order, ask us

Browse more cased axial fans, axial fans or Elta fans, or call us for help choosing the right fan.

Specifications

Model SDA350/4-1AC
Type Cased axial fan, short case
Diameter 350mm
Max airflow 2570 m³/h
Static pressure 50 Pa
Motor Single phase AC, 220-240V 50Hz, 4 pole, 1075 rpm
Power 119 W (0.54 A peak)
Noise 45 dB(A) at 3m
IP rating IP44 motor, IP55 terminal box
Warranty 1 Year Manufacturer
Overall efficiency 24.0% at best efficiency point
FMEG Below 125W, outside ErP 327/2011 limits
Case 180mm long, 356mm internal diameter, 421mm flange diameter
Flange fixings 8 holes 10mm on 395mm PCD
Impeller Ziehl-Abegg FE2owlet aerofoil with serrated trailing edges
Finish Powder coated mild steel, RAL 7045
Operating temperature -20°C to +70°C, up to 95% RH
Weight 8 kg
Wiring diagram 152-104B

Manuals & Guides

Delivery & Returns

Our Price Match Promise

Payment Methods

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

How much air does the Elta SDA350/4-1AC move?

Up to 2570 m³/h in free air and 1544 m³/h at 50 Pa.

What size duct does the SDA350/4-1AC fit?

350mm. The case has a 356mm internal diameter and 8 flange holes of 10mm on a 395mm PCD at each end, which match Elta's 061A-0350-C matching flanges.

Which speed controller do I need?

Elta list the 149-TC12 for this fan. The motor draws 0.54 A peak, so check the rating if you put more than one fan on a controller.

How noisy is it?

Elta quote 45 dB(A) at the inlet and 45 dB(A) at the outlet at 3m at full speed. Matching 1D and 2D flanged silencers (068-0350) are available to order if you need it quieter.

What power supply does it need?

A single phase 220-240V 50Hz supply. Peak current is 0.54 A at 230V, and Elta wiring diagram 152-104B applies. It must be wired by a qualified electrician with a local isolator.

Can it be mounted vertically or outside the building?

It can be mounted at any angle, horizontal or vertical. The motor is IP44 with an IP55 terminal box and the fan handles air from -20°C to +70°C, but it is designed to sit in ductwork rather than be exposed to the weather; on an external wall fit a weather cowl such as Elta SWC35/40.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)