Elta Multiflow SEL315/2A-1AC Mixed Flow Inline Fan Single Phase AC - 315mm
Suggested products
Free 14 day returns
Changed your mind or ordered the wrong unit? You have 14 days from delivery to send it back. As long as items are unused and in their original packaging, we'll arrange your refund. Just contact our team and we'll take care of the rest. Made-to-order and bespoke items are non-returnable.
Why choose eFans?
- Bulk pricing available
- Free help and advice
- Fast quotes, usually within the hour
- Huge range with next-day delivery
- Credit accounts available
Delivery and Warranty
Standard UK Mainland Delivery
If you are not in a rush, then we offer standard delivery and your order should be with you between 2-3 working days.
£7.95
Next Working Day Delivery
Place your order before 12pm Monday to Thursday and receive your order the next working day. Orders placed on Friday before 11am will be processed and delivered on Monday. (Excludes Sunday’s and Public Holidays)
£15.95
Nominated Day Delivery
We know sometimes you will need an order on a particular date in the future. Simply select this option at checkout and add what date you would like to receive the order. We will then contact you to confirm the date. If you need to change this order date then please contact us ASAP.
£15.95
Northern Ireland Delivery
We offer a flat fee rate for Northern Ireland orders, and all are 5-7 working day lead times.
£29.95
Scottish Highlands & Islands Delivery
We only offer a flat fee rate for Scottish Highland & Islands orders, and all are 5-7 working day lead times.
£45.95
Channel Islands Delivery
We only offer a flat fee rate for Channel Islands orders, and all are 5-7 working day lead times.
£45.95
Product Details
Downloads
Specifications
Product specifications
| Model | SEL315/2A-1AC |
| Type | Mixed flow inline duct fan |
| Duct size | 315mm |
| Max airflow | 2354 m³/h |
| Static pressure | 500 Pa |
| Motor | Single phase AC, 220 to 240V 50Hz, 2 pole, 2819 rpm |
| Power | 0.263 kW (1.2 A) |
| Noise | 54 dB(A) inlet, 58 dB(A) outlet at 3m |
| IP rating | IPX4 casing, IP44 terminal box |
| Warranty | 1 Year Manufacturer |
Summary
See more specification See less specification
The Elta Multiflow SEL315/2A-1AC is a 315mm mixed flow inline duct fan with a single phase 2 pole AC motor, moving up to 2354 m³/h in free air and 2189 m³/h against 100 Pa. A diagonal mixed flow impeller and 3D stator guide vanes give it far more pressure than an axial fan of the same diameter.
The motor runs at 2819 rpm on 220 to 240V 50Hz, absorbing 0.263 kW at its best efficiency point with integral thermal overload protection, and it is wired through an integral IP44 terminal box. The casing is weatherproofed to IPX4, the fan mounts at any angle on its integral bracket, and Elta give a 12 month warranty.
- 1 Phase
- AC Motor
- Up to 2354 m³/h
- Speed Controllable
What it is best used for
High pressure ventilation on 315mm duct from a single phase supply: changing rooms, gym and squash court extract, commercial kitchens behind filtered canopies, hotel and office toilet blocks. It holds 2189 m³/h at 100 Pa and 1652 m³/h at 300 Pa.
Above 350 Pa the airflow falls away sharply (540 m³/h at 400 Pa), so for higher resistance or more air choose the SEL315/2B-1AC, which still moves 2848 m³/h at 300 Pa.
Why choose this over alternatives
The SEL315/2A-1AC is the standard 315mm single phase SEL: 2354 m³/h free air for 0.263 kW. The high performance SEL315/2B-1AC uses a 0.515 kW motor to reach 3510 m³/h and holds its airflow to 400 Pa, but costs more, weighs 15 kg against 8 kg and is louder. Choose the 2A where the system is under about 300 Pa.
Installation notes
- The fan can be mounted in any orientation. Slide it into the duct and fix it with the integral mounting bracket, making sure the ductwork is not strained, and connect duct to both inlet and outlet so no moving parts are accessible.
- Elta recommend padded connection sleeves or fast clamps (018-315-CLAMP) to cut noise transmitted into the ductwork. Run the airflow in the direction marked on the casing.
- Wire into the integral IP44 terminal box to Elta diagram 152-540. Elta specify the 149-TC14 5 step transformer controller (4 A) for speed control; at lower steps the fan runs at 2640, 2425 and 1895 rpm.
- The internal thermal protection does not protect the motor if the impeller is blocked, so where that could happen fit a motor protection switch with thermal and magnetic release. Fit a means of isolation and earth the fan.
- Install indoors in a dry, condensation free space: Elta's installation manual says SEL fans must not be operated out of doors, and they are not for explosive atmospheres. Clean the impeller and casing at the recommended intervals; an upstream filter extends them.
You'll also need
- Elta 149-TC14 single phase 5 step transformer controller (4 A), the controller Elta specify for this fan.
- Elta fast clamps 018-315-CLAMP (each) and backdraught damper 018-315-DAMPER, available to order, ask us.
- Elta spigot silencers 068-0315-JF1 (300mm) to 068-0315-JF4 (1200mm), available to order, ask us.
Browse more inline mixed flow fans, inline duct fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | SEL315/2A-1AC |
| Type | Mixed flow inline duct fan |
| Duct size | 315mm |
| Max airflow | 2354 m³/h |
| Static pressure | 500 Pa |
| Motor | Single phase AC, 220 to 240V 50Hz, 2 pole, 2819 rpm |
| Power | 0.263 kW (1.2 A) |
| Noise | 54 dB(A) inlet, 58 dB(A) outlet at 3m |
| IP rating | IPX4 casing, IP44 terminal box |
| Warranty | 1 Year Manufacturer |
| Airflow at 100 Pa | 2189 m³/h |
| Airflow at 200 Pa | 1962 m³/h |
| Overall efficiency | 50.8% at best efficiency point |
| FMEG efficiency grade | N 67.4 |
| Max ambient temperature | 55°C (nameplate) |
| Breakout noise | 37 dB(A) at 3m |
| Weight | 8 kg |
| Speed controller | 149-TC14 (5 step transformer) |
| Wiring diagram | 152-540 |
Manuals & Guides
Product Description
The Elta Multiflow SEL315/2A-1AC is a 315mm mixed flow inline duct fan with a single phase 2 pole AC motor, moving up to 2354 m³/h in free air and 2189 m³/h against 100 Pa. A diagonal mixed flow impeller and 3D stator guide vanes give it far more pressure than an axial fan of the same diameter.
The motor runs at 2819 rpm on 220 to 240V 50Hz, absorbing 0.263 kW at its best efficiency point with integral thermal overload protection, and it is wired through an integral IP44 terminal box. The casing is weatherproofed to IPX4, the fan mounts at any angle on its integral bracket, and Elta give a 12 month warranty.
- 1 Phase
- AC Motor
- Up to 2354 m³/h
- Speed Controllable
What it is best used for
High pressure ventilation on 315mm duct from a single phase supply: changing rooms, gym and squash court extract, commercial kitchens behind filtered canopies, hotel and office toilet blocks. It holds 2189 m³/h at 100 Pa and 1652 m³/h at 300 Pa.
Above 350 Pa the airflow falls away sharply (540 m³/h at 400 Pa), so for higher resistance or more air choose the SEL315/2B-1AC, which still moves 2848 m³/h at 300 Pa.
Why choose this over alternatives
The SEL315/2A-1AC is the standard 315mm single phase SEL: 2354 m³/h free air for 0.263 kW. The high performance SEL315/2B-1AC uses a 0.515 kW motor to reach 3510 m³/h and holds its airflow to 400 Pa, but costs more, weighs 15 kg against 8 kg and is louder. Choose the 2A where the system is under about 300 Pa.
Installation notes
- The fan can be mounted in any orientation. Slide it into the duct and fix it with the integral mounting bracket, making sure the ductwork is not strained, and connect duct to both inlet and outlet so no moving parts are accessible.
- Elta recommend padded connection sleeves or fast clamps (018-315-CLAMP) to cut noise transmitted into the ductwork. Run the airflow in the direction marked on the casing.
- Wire into the integral IP44 terminal box to Elta diagram 152-540. Elta specify the 149-TC14 5 step transformer controller (4 A) for speed control; at lower steps the fan runs at 2640, 2425 and 1895 rpm.
- The internal thermal protection does not protect the motor if the impeller is blocked, so where that could happen fit a motor protection switch with thermal and magnetic release. Fit a means of isolation and earth the fan.
- Install indoors in a dry, condensation free space: Elta's installation manual says SEL fans must not be operated out of doors, and they are not for explosive atmospheres. Clean the impeller and casing at the recommended intervals; an upstream filter extends them.
You'll also need
- Elta 149-TC14 single phase 5 step transformer controller (4 A), the controller Elta specify for this fan.
- Elta fast clamps 018-315-CLAMP (each) and backdraught damper 018-315-DAMPER, available to order, ask us.
- Elta spigot silencers 068-0315-JF1 (300mm) to 068-0315-JF4 (1200mm), available to order, ask us.
Browse more inline mixed flow fans, inline duct fans or Elta fans, or call us for help choosing the right fan.
Specifications
| Model | SEL315/2A-1AC |
| Type | Mixed flow inline duct fan |
| Duct size | 315mm |
| Max airflow | 2354 m³/h |
| Static pressure | 500 Pa |
| Motor | Single phase AC, 220 to 240V 50Hz, 2 pole, 2819 rpm |
| Power | 0.263 kW (1.2 A) |
| Noise | 54 dB(A) inlet, 58 dB(A) outlet at 3m |
| IP rating | IPX4 casing, IP44 terminal box |
| Warranty | 1 Year Manufacturer |
| Airflow at 100 Pa | 2189 m³/h |
| Airflow at 200 Pa | 1962 m³/h |
| Overall efficiency | 50.8% at best efficiency point |
| FMEG efficiency grade | N 67.4 |
| Max ambient temperature | 55°C (nameplate) |
| Breakout noise | 37 dB(A) at 3m |
| Weight | 8 kg |
| Speed controller | 149-TC14 (5 step transformer) |
| Wiring diagram | 152-540 |
Manuals & Guides
Delivery & Returns
Our Price Match Promise
Payment Methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What duct size does the Elta SEL315/2A-1AC fit?
315mm circular duct. It slides into the duct run and fixes with its integral mounting bracket, in any orientation.
How much air does the SEL315/2A-1AC move?
Up to 2354 m³/h (0.654 m³/s) in free air, 2189 m³/h at 100 Pa and 205 m³/h at 500 Pa, the highest pressure in Elta's table for this model.
Which speed controller suits the SEL315/2A-1AC?
Elta specify the 149-TC14 single phase 5 step transformer controller (4 A). We stock it.
How noisy is the SEL315/2A-1AC?
Elta quote 54 dB(A) inlet and 58 dB(A) outlet at 3m on full speed, with 37 dB(A) breakout. Spigot silencers from 300 to 1200mm long are available.
Can the SEL315/2A-1AC be fitted outside?
No. The casing is weatherproofed to IPX4, but Elta's installation manual says SEL fans must not be operated out of doors and should be installed in dry rooms free of condensation.
What does the code SEL315/2A-1AC mean?
SEL is the Multiflow range, 315 is the diameter in mm, 2 is the number of motor poles (the letter is Elta's additional variant coding), 1 is single phase and AC is the motor type.