{"title":"Destratification Fans","description":"\u003cstyle\u003e\n\/* Neutralise the theme's height-based clamp on the collection description and hide\n   its toggle. Visibility is controlled by the \u003cdetails\u003e below instead, mirroring the\n   PDP's pdp-summary-more pattern: the author decides where the summary ends, so there\n   is no measuring, no fade, and nothing gets cut mid-sentence at any viewport. *\/\n.collection__description.expandable-content{max-height:none!important;padding-bottom:0!important}\n.collection__description .expandable-content__toggle{display:none!important}\n.collection__description,.collection__description .rte{overflow:visible!important}\n\n#efans-subnav{display:flex;flex-wrap:wrap;align-items:center;gap:8px;margin:44px 0 4px;padding:4px 0 8px;position:relative}\n#efans-subnav \u003e a{flex:0 0 auto;white-space:nowrap;display:inline-flex;align-items:center;padding:12px 14px;border:1px solid #d6d6d6;border-radius:999px;background:#fff;color:#222;font-size:14px;font-weight:500;line-height:1.3;text-decoration:none;cursor:pointer;transition:border-color .15s,background-color .15s,color .15s}\n#efans-subnav \u003e a:hover{border-color:#000;color:#000}\n#efans-subnav \u003e a.efx-active,#efans-subnav \u003e a.efx-active:hover{background:#000;border-color:#000;color:#fff}\n#efans-subnav \u003e a.efx-active::after{content:\"\\00d7\";margin-left:8px;font-size:16px;line-height:1}\n\n.efx-more{margin-top:28px}\n.efx-more \u003e summary{list-style:none;cursor:pointer;display:inline-block;color:var(--text-color);text-decoration:underline;text-decoration-style:dotted;text-underline-offset:3px}\n.efx-more \u003e summary::-webkit-details-marker{display:none}\n.efx-more \u003e summary:hover{color:var(--heading-color)}\n.efx-more .efx-more__open{display:none}\n.efx-more[open] \u003e summary .efx-more__closed{display:none}\n.efx-more[open] \u003e summary .efx-more__open{display:inline}\n.efx-more__content{margin-top:24px}\n.efx-more__content h2:first-child{margin-top:0}\n\u003c\/style\u003e\n\n\u003cp\u003eDestratification fans, also called anti-stratification fans, destrat fans, sweep ceiling fans or ceiling sweep fans, solve the single biggest energy waste in any tall heated building: warm air rising and sitting uselessly against the roof while the occupied zone stays cold. eFans is a UK Hydor stockist and supplies the full Hydor HCF destratification range: HCF900 (36\"), HCF1200 (48\") and HCF1400 (56\").\u003c\/p\u003e\n\n\u003cdetails class=\"efx-more\"\u003e\n\u003csummary\u003e\u003cspan class=\"efx-more__closed\"\u003eRead more\u003c\/span\u003e\u003cspan class=\"efx-more__open\"\u003eRead less\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"efx-more__content\"\u003e\n\n\u003cp\u003eAll three are 1-phase, single-speed AC motors, speed-controllable via a standard fan speed controller, and designed for permanent ceiling mounting in warehouses, factories, distribution centres, workshops, gymnasiums, sports halls, churches, village halls, agricultural buildings and any space with high ceilings and gas, oil or electric heating. Running a correctly sized destratification fan typically pays back the purchase price within one heating season on reduced gas or electricity bills. In UK stock with next-day delivery and trade pricing on multiple-unit installs.\u003c\/p\u003e\n\u003ch2\u003eWhat are destratification fans?\u003c\/h2\u003e\n\u003cp\u003eDestratification fans are ceiling-mounted sweep fans that mix the warm air trapped near the roof of a tall heated building back down into the occupied zone. In any heated space, warm air is less dense than cold air and rises. In a typical 6 to 10m warehouse or church, the temperature at the apex can easily be 8 to 15°C warmer than at floor level. That stratified warm air does nothing useful; the heating system is forced to run harder and longer to keep the occupied zone comfortable. A destratification fan pushes that warm air back down, evens out the temperature profile top-to-bottom, and cuts heating demand typically by 20 to 30%.\u003c\/p\u003e\n\u003ch2\u003eHow do destratification fans work?\u003c\/h2\u003e\n\u003cp\u003eUnlike HVLS fans, which move huge volumes of air for occupant cooling at low speed, destratification fans are smaller, faster and purpose-designed to recirculate warm ceiling air. The Hydor HCF range uses a traditional-style sweep ceiling fan blade running at moderate speed, directed downward, to pull the hottest air down from the apex and mix it back through the occupied zone. Fans can usually run continuously through the heating season on a low speed setting, or be wired through a thermostat or controller that triggers them when roof-level temperature exceeds a setpoint. Noise levels are low enough for occupied office, retail and place-of-worship applications.\u003c\/p\u003e\n\u003ch2\u003eHow to choose the right destratification fan\u003c\/h2\u003e\n\u003cp\u003eSelecting the right destratification fan depends on the size, height, and use of your commercial or industrial space. Consider ceiling height, as higher ceilings require more powerful fans to effectively circulate warm air.\u003c\/p\u003e\n\u003cp\u003eAirflow rate (measured in m³\/h) is key to ensure the warm air is redistributed efficiently without creating drafts. Fan type, energy efficiency, and noise levels should also be evaluated to suit the environment.\u003c\/p\u003e\n\u003ch2\u003eWhich Hydor HCF size do I need?\u003c\/h2\u003e\n\u003cp\u003eHydor HCF900 (36\"\/900mm) suits smaller workshops, offices, classrooms and spaces up to roughly 4 to 5m ceiling height. HCF1200 (48\"\/1200mm) is the most common choice: warehouses, factory units, gyms, village halls and churches with 5 to 8m ceilings. HCF1400 (56\"\/1400mm) is specified for large industrial units, distribution centres, sports halls and high-ceilinged churches with 7 to 10m+ apex. As a rule of thumb, one HCF1200 covers roughly 100 to 150m² of floor at typical warehouse ceiling heights; space fans on a grid rather than clustering them. For ceilings over 10m or buildings with radiant tube or warm-air heaters aimed high, talk to us about the right approach before specifying.\u003c\/p\u003e\n\u003ch2\u003eWhat buildings use destratification fans?\u003c\/h2\u003e\n\u003cp\u003eWarehouses, distribution centres, light industrial units, engineering workshops, MOT bays, vehicle showrooms, agricultural buildings and barns, gymnasiums and sports halls, swimming pool halls, churches and places of worship, village halls and community centres, school halls, large retail units, garden centres, and any commercial or industrial space with a heated apex above 5m. The payback is strongest in buildings heated by gas warm-air heaters, radiant tubes, oil-fired unit heaters or electric overhead heaters, all of which tend to deposit heat upward and suffer badly from stratification.\u003c\/p\u003e\n\u003ch2\u003eHow much energy do destratification fans save?\u003c\/h2\u003e\n\u003cp\u003eTypical savings are 20 to 30% of heating fuel cost in a stratified building, though some installs report higher. The saving depends on ceiling height (taller means a bigger gradient and a bigger saving), heating system type (warm-air and radiant benefit most), insulation quality, and how long the heating runs. Payback on a Hydor HCF1200 installed in a typical UK warehouse is usually under one heating season on reduced gas bills alone. Fans themselves consume very little electricity, typically 60 to 120W each depending on size and speed, so the net saving is almost entirely captured.\u003c\/p\u003e\n\u003ch2\u003eAre Hydor HCF fans speed controllable?\u003c\/h2\u003e\n\u003cp\u003eYes. All three Hydor HCF fans, HCF900, HCF1200 and HCF1400, are single-phase AC motors that work with standard fan speed controllers. For most destratification applications the fan runs continuously at a low speed through the heating season, so a simple 5-step controller or electronic speed controller is specified alongside. For multi-fan installs we recommend one controller per zone or per three-to-five fans rather than trying to drive an entire warehouse off a single small controller. Wire through a thermostat or timer if you want the fans to switch off in summer or outside working hours.\u003c\/p\u003e\n\u003ch2\u003eAt what height should destratification fans be mounted?\u003c\/h2\u003e\n\u003cp\u003eMount as high as practical, as close to the roof apex as the structure allows, so the fan draws from the hottest layer. A typical install uses a downrod or drop-rod to position the fan blades 500 to 1000mm below the apex, clear of any roof trusses or services. Minimum clearance from floor to blade tip should be 2.7m for occupant safety. In pitched-roof buildings, fans are usually sited under the ridge line and spaced down the length of the building. Ensure fixings are made into structural steelwork or a suitable timber purlin, never into plasterboard or a suspended ceiling alone.\u003c\/p\u003e\n\u003ch2\u003eCan destratification fans be used in cold or unheated buildings?\u003c\/h2\u003e\n\u003cp\u003eOnly if there is a meaningful temperature gradient to destratify. In an unheated barn or warehouse with no heating source, there is no stratified warm layer to recirculate, so a destratification fan adds nothing. The same fan can however be run in summer on a higher speed for occupant cooling, functionally the same as a traditional ceiling fan, so the purchase is not wasted if the building is used year-round. For buildings that are only occasionally heated (churches, village halls, weekend-use units), fans can be wired on the same circuit as the heating so they come on together.\u003c\/p\u003e\n\u003ch2\u003eHow many destratification fans do I need for a warehouse?\u003c\/h2\u003e\n\u003cp\u003eThe number depends on ceiling height, floor area, heat source layout, and zoning. Large warehouses usually need several evenly spaced units to ensure balanced airflow and full coverage. A proper airflow assessment avoids dead spots and optimises performance. Send us your building dimensions and heating type and we will size the install for you.\u003c\/p\u003e\n\u003ch2\u003eAre destratification fans suitable for sports halls and leisure centres?\u003c\/h2\u003e\n\u003cp\u003eYes. They work well in sports halls, gyms, and leisure centres with high ceilings, where warm air gathers above the occupied zone. Destratification fans reduce temperature differences, improve comfort, and help lower heating costs by smoothing HVAC loads.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdiv id=\"efans-subnav\"\u003e\n\u003ca rel=\"nofollow\" data-tag=\"size_900mm\" href=\"\/collections\/destratification-fans\/size_900mm\"\u003e900mm (36\")\u003c\/a\u003e\n\u003ca rel=\"nofollow\" data-tag=\"size_1200mm\" href=\"\/collections\/destratification-fans\/size_1200mm\"\u003e1200mm (48\")\u003c\/a\u003e\n\u003ca rel=\"nofollow\" data-tag=\"size_1400mm\" href=\"\/collections\/destratification-fans\/size_1400mm\"\u003e1400mm (56\")\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cscript\u003e\n(function(){var n=document.getElementById('efans-subnav');if(!n)return;var base='\/collections\/destratification-fans';\nvar p=location.pathname.replace(\/\\\/$\/,''),seg=p.indexOf(base+'\/')===0?decodeURIComponent(p.slice(base.length+1)):'';\nvar cur=seg?seg.split('+').filter(Boolean):[];\nfunction url(list){return list.length?base+'\/'+list.join('+'):base;}\nn.querySelectorAll('a[data-tag]').forEach(function(a){var t=a.getAttribute('data-tag'),g=t.split('_')[0],on=cur.indexOf(t)\u003e-1;\na.setAttribute('href',url(on?cur.filter(function(x){return x!==t;}):cur.filter(function(x){return x.split('_')[0]!==g;}).concat([t])));\nif(on){a.classList.add('efx-active');a.setAttribute('aria-pressed','true');a.title='Remove this filter';}});})();\n\u003c\/script\u003e\n\u003c!-- Schema: BreadcrumbList --\u003e\n\u003c!-- Schema: Organization --\u003e\n\u003c!-- Schema: Speakable --\u003e\n\u003c!-- Schema: FAQPage --\u003e\n","products":[{"product_id":"hydor-48-destratification-sweep-ceiling-fan-hcf1200","title":"Hydor 48\" Destratification Sweep Ceiling Fan HCF1200","description":"\u003cp\u003eThe Hydor HCF1200 is a 48\" (1200 mm) destratification sweep ceiling fan that redistributes air, pushing warm air trapped at ceiling level back down to occupancy level. It's a high-performance air-circulation fan that generates an optimised airflow to cover large areas, ideal for reducing heating costs and evening out temperature in tall spaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir delivery up to 12600 m³\/h (3.50 m³\/s); low power consumption of 55 W\u003c\/li\u003e\n\u003cli\u003e48\" (1200 mm) sweep; 315 r\/min\u003c\/li\u003e\n\u003cli\u003eLong-life ball bearings and silent automatic shutters\u003c\/li\u003e\n\u003cli\u003eSafety cable included; single-phase 220 to 240 V, 50 Hz\u003c\/li\u003e\n\u003cli\u003eSpeed controllable via HCF1.7 controller (HCFC1.7 reversible option, sold separately)\u003c\/li\u003e\n\u003cli\u003eIvory finish; suitable for operation up to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial warehousing, gymnasiums, factories, stores and offices\u003c\/li\u003e\n\u003cli\u003eCeiling mounting in tall or large spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eCeiling-mounted using the included safety cable. Should be installed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHydor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHCF1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDestratification sweep ceiling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 mm (48\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir delivery (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12600 m³\/h (3.50 m³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V, 1~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIvory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eManuals \u0026amp; Guides\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Destratification_Ceiling_Fan_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Destratification Ceiling Fan Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Ceiling_Fan_Installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Ceiling Fan Installation Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"Hydor","offers":[{"title":"Default Title","offer_id":41032157757596,"sku":"50491","price":94.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/hydor-destratification-sweep-ceiling-fan-hcf_99a8811f-b0f3-4378-b004-90142ca438a7.jpg?v=1728854145"},{"product_id":"hydor-56-destratification-sweep-ceiling-fan-hcf1400","title":"Hydor 56\" Destratification Sweep Ceiling Fan HCF1400","description":"\u003cp\u003eThe Hydor HCF1400 is a 56\" (1400 mm) destratification sweep ceiling fan that redistributes air, pushing warm air trapped at ceiling level back down to occupancy level. It's a high-performance air-circulation fan that generates an optimised airflow to cover large areas, ideal for reducing heating costs and evening out temperature in tall spaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir delivery up to 14112 m³\/h (3.92 m³\/s); low power consumption of 67 W\u003c\/li\u003e\n\u003cli\u003e56\" (1400 mm) sweep; 290 r\/min\u003c\/li\u003e\n\u003cli\u003eLong-life ball bearings and silent automatic shutters\u003c\/li\u003e\n\u003cli\u003eSafety cable included; single-phase 220 to 240 V, 50 Hz\u003c\/li\u003e\n\u003cli\u003eSpeed controllable via HCF1.7 controller (HCFC1.7 reversible option, sold separately)\u003c\/li\u003e\n\u003cli\u003eIvory finish; suitable for operation up to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial warehousing, gymnasiums, factories, stores and offices\u003c\/li\u003e\n\u003cli\u003eCeiling mounting in tall or large spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eCeiling-mounted using the included safety cable. Should be installed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHydor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHCF1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDestratification sweep ceiling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 mm (56\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir delivery (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14112 m³\/h (3.92 m³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V, 1~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIvory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eManuals \u0026amp; Guides\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Destratification_Ceiling_Fan_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Destratification Ceiling Fan Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Ceiling_Fan_Installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Ceiling Fan Installation Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"Hydor","offers":[{"title":"Default Title","offer_id":43154260984042,"sku":"50492","price":100.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/hydor-destratification-sweep-ceiling-fan-hcf_bbbcba1b-c47c-420a-b8fc-c1a86848093c.jpg?v=1728854181"},{"product_id":"hydor-36-destratification-sweep-ceiling-fan-hcf900","title":"Hydor 36\" Destratification Sweep Ceiling Fan HCF900","description":"\u003cp\u003eThe Hydor HCF900 is a 36\" (900 mm) destratification sweep ceiling fan that redistributes air, pushing warm air trapped at ceiling level back down to occupancy level. It's a high-performance air-circulation fan that generates an optimised airflow to cover large areas, ideal for reducing heating costs and evening out temperature in tall spaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir delivery up to 8100 m³\/h (2.25 m³\/s); low power consumption of 43 W\u003c\/li\u003e\n\u003cli\u003e36\" (900 mm) sweep; 330 r\/min\u003c\/li\u003e\n\u003cli\u003eLong-life ball bearings and silent automatic shutters\u003c\/li\u003e\n\u003cli\u003eSafety cable included; single-phase 220 to 240 V, 50 Hz\u003c\/li\u003e\n\u003cli\u003eSpeed controllable via HCF1.7 controller (HCFC1.7 reversible option, sold separately)\u003c\/li\u003e\n\u003cli\u003eIvory finish; suitable for operation up to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial warehousing, gymnasiums, factories, stores and offices\u003c\/li\u003e\n\u003cli\u003eCeiling mounting in tall or large spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eCeiling-mounted using the included safety cable. Should be installed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHydor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHCF900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDestratification sweep ceiling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900 mm (36\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir delivery (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8100 m³\/h (2.25 m³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V, 1~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIvory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eManuals \u0026amp; Guides\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Destratification_Ceiling_Fan_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Destratification Ceiling Fan Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/Hydor_HCF_Ceiling_Fan_Installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHydor HCF Ceiling Fan Installation Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"Hydor","offers":[{"title":"Default Title","offer_id":48206969241921,"sku":"HCF900","price":91.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0355\/3932\/0965\/files\/hydor-destratification-sweep-ceiling-fan-hcf.jpg?v=1728853935"}],"url":"https:\/\/www.efans.co.uk\/collections\/destratification-fans\/size_900mm.oembed","provider":"eFans Direct Ltd","version":"1.0","type":"link"}